Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Post-processing of HVOF-sprayed WC-10Co-4Cr coatings by laser remelting: Microstructural evolution and corrosion behavior
Department of Mechanical Engineering, Thapar Institute of Engineering and Technology, Patiala, Punjab (IND).
Department of Industrial and Production Engineering, Dr. B R Ambedkar National Institute of Technology, Jalandhar, Punjab (IND).
Department of Mechanical Engineering, JSS University, Noida, Uttar Pradesh (IND).
University West, Department of Engineering Science, Division of mechanical engineering. (KAMPT)
2027 (English)In: International journal of refractory metals & hard materials, ISSN 0263-4368, Vol. 143, article id 108180Article in journal (Refereed) Published
Abstract [en]

HVOF-sprayed WC-10Co-4Cr coatings are widely used to protect steel components in marine and hydropower applications. The WC-10Co-4Cr coatings deposited on IS-2062 steel by HVOF spraying were post processed by laser remelting to alter the surface morphology and improve the corrosion performance. Scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectroscopy (EDS), three-dimensional surface profilometry, microhardness testing, and potentiodynamic polarization were used for the characterization of the coatings. The HVOF process resulted in dense coatings with thicknesses ranging from 174 to 190 μm. Laser remelting produced uniformly distributed circular remelted regions with a diameter of approximately 650 μm and the surface hardness increased by 19.5%, from (1065 ± 8 HV0.3) to (1273 ± 11HV0.3). The laser remelting process reduced the coating porosity from 2.413% to 0.807%. The XRD analysis showed WC and Co₃W₃C as the main phases, while a weak peak of W₂C was observed in the as-sprayed coating; no distinct W₂C peak was identified after laser remelting. Electrochemical measurements showed 43.3% decrease in corrosion current density from (12.80 ± 0.7) × 10−3 to (7.26 ± 0.3) × 10−3 A.cm−2 indicating better corrosion resistance. The improved performance is attributed to the laser-induced microstructural refinement, selective modification of the CoCr binder phase, reduction in porosity, and enhanced passivation associated with Cr-rich oxide formation. The proposed post-processing approach provides a convenient route to improve the durability of HVOF-sprayed WC-10Co-4Cr coatings in aggressive service environments

Place, publisher, year, edition, pages
Elsevier Ltd , 2027. Vol. 143, article id 108180
Keywords [en]
Coating; Corrosion; HVOF; Laser remelting; WC-10Co-4Cr
National Category
Manufacturing, Surface and Joining Technology
Research subject
Production Technology
Identifiers
URN: urn:nbn:se:hv:diva-26451DOI: 10.1016/j.ijrmhm.2026.108180ISI: 001911643700001Scopus ID: 2-s2.0-105054022087OAI: oai:DiVA.org:hv-26451DiVA, id: diva2:2114557
Available from: 2026-11-02 Created: 2026-11-02 Last updated: 2026-11-02

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Singh Kumar, Navneet

Search in DiVA

By author/editor
Singh Kumar, Navneet
By organisation
Division of mechanical engineering
In the same journal
International journal of refractory metals & hard materials
Manufacturing, Surface and Joining Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf