Konkurrensanalys av tre olika nedgång likströmsomriktare
University West, Department of Engineering Science.
2025 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Denna rapport behandlar elektromagnetiska störningar (EMI) för tre olika nedgång likströmsomriktare. Med tanke på teknologins utvecklig i samhället är elektromagnetisk kompatibilitet (EMC) ett viktigt område att ta hänsyn till. Elektriska applikationer är beroende av att vara elektromagnetiskt kompatibla för att inte orsaka störningar hos sig själv, men även hos andra närliggande applikationer.

Syftet med arbetet är att identifiera vilka störningar som genereras hos de tre omriktarna och därefter rekommendera en skärmningsmetod. Konsekvenser av EMC problem kan ha livshotande effekter för konsumenten som använder sig av den elektriska applikationen. Ett exempel på hur EMC kan leda till alvarliga konsekvenser är att säkerhetssystemet i en bil inte fungerar korrekt.Resultatet av störningarna visas med hjälp av en frekvensanalysator och är kopplat till en TEM-cell kammare som tar upp de elektromagnetiska störningarna. Resultatet visadestörningar i olika frekvensområden. Skärmningsmetoden som undersöktes visade att störningarna dämpades, vilket tyder på elektrisk fält som orsakar störningarna. Det rekommenderades därför skärmningsmetoden som undersöktes.

Abstract [en]

This report deals with electromagnetic interference (EMI) for three different step-down DC/DC converters. Given the development of technology in society, electromagnetic compatibility (EMC) is an important area to consider. Electrical applications depend on being electromagnetically compatible in order not to cause interference to themselves, but also to other nearby applications.

The purpose of the work is to identify which interference is generated by the three converters and then recommend a shielding method to reduce these interferences. Consequences of EMC problems can have life-threatening effects for the consumer who uses the electrical application. An example of how EMC can lead to serious consequences can be, among other things, that the safety systems in a car do not function correctly.The result of the interference is shown using a frequency analyzer that is connected to a TEM cell chamber that records the electromagnetic interference. The result showed interference in different frequency ranges. It also turned out that the data sheet for each converter did not match reality. The shielding method that was recommended was to reduce the electrical interference, E-field. This resulted in the interference being reduced.

Place, publisher, year, edition, pages
2025. , p. 36
Keywords [sv]
likströmsomriktare, elektromagnetiska störningar
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-23099Local ID: EXE512OAI: oai:DiVA.org:hv-23099DiVA, id: diva2:1942316
Subject / course
Electrotechnology
Educational program
Elektroingenjör Fordon
Supervisors
Examiners
Available from: 2025-03-10 Created: 2025-03-04 Last updated: 2025-09-30Bibliographically approved

Open Access in DiVA

fulltext(1608 kB)113 downloads
File information
File name FULLTEXT01.pdfFile size 1608 kBChecksum SHA-512
4b410293a31f26919c6971fd3b6016374def14dc961367af6c8488e8a37096b80301d50a7b07d7e590502d5a96fa9a1383612603e77827b90db63880d6aecb44
Type fulltextMimetype application/pdf

By organisation
Department of Engineering Science
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 113 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 2937 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf