Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Införande av automatisk lindningskopplare på 10 kV/0.4 kV transformatorer
University West, Department of Engineering Science.
2024 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Introduction of Automatic Tap Changers on 10 kV/0.4 kV Transformers (English)
Abstract [sv]

Denna rapport undersöker implementeringen av en automatisk lindningskopplare (On-Load Tap Changer, OLTC) på en 10 kV/0,4 kV-transformator vid Station A inom Göteborg Energi Nät AB. Syftet är att analysera hur OLTC-tekniken kan förbättra spänningsregleringen och stabiliteten i lågspänningsnät med dynamiska energibehov.

Studien fokuserar på två kunder: Kund A, som använder batterilagring, och Kund B, som har en solcellsanläggning. Dessa tekniker skapar betydande utmaningar i form av spänningsvariationer i nätet.

Resultaten visar att OLTC effektivt stabiliserar spänningen genom kontinuerlig och avbrottsfri reglering. Beräkningar visar att tekniken kan hantera spänningsvariationer mellan 231 V och 243 V för Kund A samt mellan 235 V och 242 V för Kund B, vilket säkerställer att spänningen hölls inom toleransgränserna. Analysen visade att OLTC:s justeringskapacitet på ±2,5 % är tillräcklig för att hantera dessa variationer. 

Ekonomisk analys indikerar att OLTC är en långsiktigt lönsam lösning, med en återbetalningstid på cirka 9,6 år vid två årliga justeringar. Vid dagliga justeringar har OLTC kapacitet för upp till 27 växlingar per dag, vilket gör den särskilt väl lämpad för moderna elnät med höga krav på flexibilitet.

Fyra scenarier har analyserats för att utvärdera sekundärspänningen under olika förhållanden, inklusive kombinationer av konsumtion och produktion från Kund A och Kund B. Dessa scenarier bidrar till en djupare förståelse för hur OLTC hanterar spänningsvariationer i praktiken.

Utöver de tekniska förbättringarna rekommenderar studien dedikerade lösningar, såsom en egen transformator för Kund A, för att minska belastningen på nätet och ytterligare förbättra stabiliteten. Arbetet bidrar med viktiga insikter om hur OLTC-tekniken kan möta de ökande kraven på flexibilitet och tillförlitlighet i framtidens elnät.

Abstract [en]

This report examines the implementation of an automatic tap changer (On-Load Tap Changer, OLTC) on a 10 kV/0.4 kV transformer at Station A within Göteborg Energi Nät AB. The purpose is to analyze how OLTC technology can enhance voltage regulation and stability in low-voltage networks with dynamic energy demands.

The study focuses on two customers: Customer A, who utilizes battery storage, and Customer B, who operates a solar power system. These technologies present significant challenges in the form of voltage variations within the network.The results show that OLTC effectively stabilizes voltage through continuous and uninterrupted regulation. Calculations indicate that the technology can handle voltage variations ranging from 231 V to 243 V for Customer A and from 235 V to 242 V for Customer B, ensuring that voltage levels remain within acceptable tolerance limits.

The analysis demonstrated that OLTC's adjustment capacity of ±2.5% is sufficient to manage these variations.Economic analysis indicates that OLTC is a cost-effective long-term solution, with a payback period of approximately 9.6 years for two annual adjustments. For daily adjustments, OLTC has the capacity to perform up to 27 switching operations per day, making it particularly wellsuited for modern power grids with high flexibility requirements.

Four scenarios were analyzed to evaluate the secondary voltage under different conditions, including combinations of consumption and production from Customer A and Customer B. These scenarios provide deeper insights into how OLTC manages voltage variations in practice.

In addition to technical improvements, the study recommends dedicated solutions, such as a separate transformer for Customer A, to reduce the load on the network and further enhance stability. This work provides valuable insights into how OLTC technology can address the increasing demands for flexibility and reliability in future power grids, .

Place, publisher, year, edition, pages
2024. , p. 26
Keywords [sv]
automatisk lindningskopplare, transformatorer
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-22984Local ID: EXE512OAI: oai:DiVA.org:hv-22984DiVA, id: diva2:1935746
Subject / course
Electrotechnology
Educational program
Elektroingenjör - Elkraft
Supervisors
Examiners
Available from: 2025-02-14 Created: 2025-02-07 Last updated: 2025-09-30Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Department of Engineering Science
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 177 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf