Kontrollplan för inspektion av pulpeter, skåp, lådor samt internkablage
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
2020 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Control plan for one-piece consoles, cabinets, junction boxes and internal wiring (English)
Abstract [sv]

I detta examensarbete tas kontrollplaner av pulpeter, skåp, lådor samt internkablage inom Ringhals kärnkraftverk fram för att skapa bättre översikt. Arbetet inkluderar två olika typer av objekt; kopplingslådor med beteckning .41 i ritningar och skåp med krav på elektromagnetisk störtålighet. Fortsättningsvis kommer rapporten därför att delas upp i två separata områden på grund av att de nämnda objekten kräver skilda kontrollplaner.

Kopplingslådor .41

I framtagningen av kontrollplanen krävdes kännedom om kopplingslådorna, miljöförhållanden samt potentiella fel. Kopplingslådorna som är hundratals till antal kan variera till det yttre och inre. Många av funktions felen orsakas av åldringseffekter som beror på degraderings mekanismer i synergi med omgivningen. Arbetet att ta fram ett statistiskt urval, som ska genomgå visuell inspektion, har skett i samråd med expertis inom kopplingslådor respektive expertis inom statistik. Antal lådor har jämförts med statistisk beräkningsmodell för att säkerställa att en tillräckligt stor mängd har blivit utvald för att översikten av .41-lådor ska anses vara av god art. Den framtagna kontrollplanen består utav statistiskt urval, åldringsanalys av degraderingsmekanismer, acceptans kriterier och dokumentation avsedda för visuella inspektioner. Trots den stora variationen av .41-lådor och miljöförhållanden anser författarna att den framtagna kontrollplanen är heltäckande och omfattar även avvikande lådor och miljöer.

EMC-skåp

Inget statistiskt urval har skett i arbetet med störningståliga skåp på grund av att det inte ingick i projektet då EMC-skåpen är färre till antalet än .41-lådor. Skåpets konstruktion har stor betydelse för dämpning av elektromagnetiska störningar. Komponenter påverkas av olika degraderingsmekanismer beroende på material som gör att livslängden försämras. Degraderingsmekanismerna har sammanställts i en åldringsanalys som del i arbetet att ta fram kontrollplanen. Acceptanskriterierna baseras på åldringsanalysen och har i sin tur resulterat i dokumentation som ska användas under visuella inspektioner. Den framtagna kontrollplanen bedöms uppfylla projektets huvudmål att skapa bättre översikt av EMC-skåp. Författarna anser dock att den resulterande kontrollplanen skulle kunna ha sett annorlunda ut och ändå uppnå huvudmålet. Till exempel fler förebyggande åtgärder som att byta packning för att förlänga tidsintervallet mellan inspektionerna.

Abstract [en]

In this thesis control plans for junction boxes, cabinets, one-piece consoles and internal wiring within Ringhals Nuclear Power Plant are created to give a better overview. This work includes two different types of objects: junction boxes labeled .41 in drawings and cabinets with requirements for electromagnetic noise immunity. Consequently, the report will therefore be divided into two separate areas because the mentioned objects require different control plans

Junction boxes .41

In the development of the control plan, knowledge about junction boxes, environmental conditions and potential failures were required. The junction boxes that are hundreds in number can vary to the exterior and interior. Many of the malfunctions are caused by aging effects due to degradation mechanisms in synergy with the environments. The work to determine a statistical sample, which will be controlled by visual inspection, has been carried out in consultation with expertise in junction boxes and statistics. The number of boxes has been compared to the statistical calculation model to ensure that the amount is enough to provide an overview of .41 boxes. The developed control plan consists of an aging analysis of degradation mechanisms, acceptance criteria and documentation intended for visual inspections. Despite the wide variety of .41 boxes and environmental conditions, the authors consider the developed control plan comprehensive and it also includes divergent boxes and environments.

EMC cabinet

No statistical selection has been taken place in the work with interference resistance cabinets because it was not included in this project and the EMC cabinets are fewer in number than the .41 boxes. The construction of the cabinet is important for the suppression of electromagnetic interference. Components are affected by different degradation mechanisms depending on material which affect the aging negative. The degradation mechanisms have been compiled in an aging analysis as part of the work to develop the control plan. The acceptance criteria are based on the aging analysis and in turn result in documentation to be used in visual inspections. The control plan developed is expected to meet the main goal of the project to create a better overview of EMC cabinets. The authors believe that the resulting control plan could have looked differently and still achieve the main goal. For example, more preventative measures such as changing the gasket to extend the time interval between inspections.

Place, publisher, year, edition, pages
2020. , p. 39
Keywords [en]
Kontrollplaner, kpooplingslådor
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-15226Local ID: EXE511OAI: oai:DiVA.org:hv-15226DiVA, id: diva2:1446330
Subject / course
Electrotechnology
Educational program
Elektroingenjör - Elkraft
Supervisors
Examiners
Available from: 2020-07-07 Created: 2020-06-24 Last updated: 2025-09-30Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 146 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf