Change search
Refine search result
1 - 2 of 2
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Rows per page
  • 5
  • 10
  • 20
  • 50
  • 100
  • 250
Sort
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
  • Standard (Relevance)
  • Author A-Ö
  • Author Ö-A
  • Title A-Ö
  • Title Ö-A
  • Publication type A-Ö
  • Publication type Ö-A
  • Issued (Oldest first)
  • Issued (Newest first)
  • Created (Oldest first)
  • Created (Newest first)
  • Last updated (Oldest first)
  • Last updated (Newest first)
  • Disputation date (earliest first)
  • Disputation date (latest first)
Select
The maximal number of hits you can export is 250. When you want to export more records please use the Create feeds function.
  • 1.
    Hagqvist, Petter
    et al.
    University West, Department of Engineering Science, Division of Automation and Computer Engineering.
    Sikström, Fredrik
    University West, Department of Engineering Science, Division of Process and Product Development.
    Christiansson, Anna-Karin
    University West, Department of Engineering Science, Division of Automation and Computer Engineering.
    Lennartson, Bengt
    Chalmers.
    Emissivity compensated spectral pyrometry for varying emissivity metallic measurands2014In: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 25, no 2, p. 025010-Article in journal (Refereed)
    Abstract [en]

    A novel method for converting electromagnetic spectral radiance information into emperature measurements is presented. It allows for varying spectral emissivity of the metallic measurand during the course of the measurement. Such variations are due to e.g. thermal oxidation or temperature dependent emissivity. Based on the assumption that emissivity changes with time and temperature in a continuous manner, it is further assumed that an emissivity estimate at one sample instance can be derived from the estimated emissivity found at the previous samples together with updated spectral information. This leads to successive recalculations of spectral emissivity together with corresponding temperature values. The proposed algorithm has been proven to give accurate temperature estimates from a measurement based on data captured by a standard UV-Vis spectrophotometer even for an oxidizing Ti-6Al-4V specimen in a temperature range between 900K and 1400K. The method however, is not limited to these wavelength- or temperature-ranges.

  • 2.
    Hagqvist, Petter
    et al.
    University West, Department of Engineering Science, Division of Automation and Computer Engineering.
    Sikström, Fredrik
    University West, Department of Engineering Science, Division of Process and Product Development.
    Christiansson, Anna-Karin
    University West, Department of Engineering Science, Division of Automation and Computer Engineering.
    Lennartson, Bengt
    Chalmers.
    Emissivity compensated spectral pyrometry-algorithm and sensitivity analysis2014In: Measurement science and technology, ISSN 0957-0233, E-ISSN 1361-6501, Vol. 25, no 2, p. 025011-Article in journal (Refereed)
    Abstract [en]

    In order to solve the problem of non-contact temperature measurements on an object with varying emissivity, a new method is herein described and evaluated. The method uses spectral radiance measurements and converts them to temperature readings. It proves to be resilient towards changes in spectral emissivity and tolerates noisy spectral measurements. It is based on an assumption of continuous changes in emissivity and uses historical values of spectral emissivity and temperature for estimating current spectral emissivity.

    The algorithm, its constituent steps and accompanying parameters are described and discussed. A thorough sensitivity analysis of the method is carried out through simulations. No rigorous instrument calibration is needed for the presented method and is therefore industrially tractable.

1 - 2 of 2
CiteExportLink to result list
Permanent link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf