Abstract [sv]

Detta examensarbete har utförts genom ÅF Industry i Trollhättan. Syftet med arbetet är att jämföra två elektriska fördelningssystem i medicinska utrymmen. I sjukhusmiljöer är tillgängligheten av elförsörjning av största vikt. Spänningsbortfall för livsuppehållande utrustning kan få förödande konsekvenser för berörd patient. Svensk standard förespråkar TN-S-system gentemot den europeiska standarden som anser att IT-system är mest lämpligt i dessa utrymmen. Genom att belysa dessa två systems för- och nackdelar kan ett samlat underlag sammanställas som senare används som beslutsunderlag för framtida kunder. Examensarbetet exemplifieras på Östra sjukhuset där befintligt IT-system skall uppgraderas.Skillnaden mellan dessa två fördelningssystem är deras förbindelse med jordpotential. TN-S-system har direkt förbindelse med jord jämfört med IT-system som är helt eller delvis isolerat från jord. Jordfel i TN-S-system kan generera höga felströmmar vilket kan jämföras med IT-system där minimal felström uppstår vid isolationsfel. IT-system och dess isolationsövervakningssystem kan dock anses som mer komplext jämfört med TN-S som är ett vanligare och mer vedertaget fördelningssystem i Sverige.Rapporten konstaterar att IT-system har en stor fördel gentemot TN-S-system. Anledningen är att eventuella jordfelsströmmar i TN-S-system kan bli så pass höga att säkring eller jordfelsbrytare riskerar frånkoppla fördelningssystemet. Denna problematik existerar inte i IT-system då endast små felströmmar uppstår vid isolationsfel. Rekommendationen är att bestycka dessa utrymmen med IT-system med tillhörande isolationsövervakning. Denna tekniska lösning medför tillfredsställande person- och patientsäkerhet med avseende mot elsäkerheten.

Abstract [en]

This bachelor thesis has been carried out at AF Industry. The purpose of the thesis is to compare two electric distribution systems for medical areas. In medical areas the availability of electric power always has to be maintained. Power failure of life supporting equipment will generate major risks to the patient in question. Swedish standard promotes TN-S-systems compared to the European standard that promotes IT-systems for medical areas. By comparing the advantage and disadvantage of these two systems there can be a complete report compiled, which purpose is to be used to support decision making for future customers. This bachelor thesis will be exemplified in Östra sjukhuset where existing IT-systems will be upgraded.The basic difference between these two electric power systems is their connection to earth. TN-S-systems has direct connection to earth compared to IT-systems that has none or partially connection with earth. Earth fault in TN-systems can generate major current compared to IT-systems where isolations fault generates minimal current. However IT-systems and their isolation monitoring systems might appear as a more complex system compared to TN-S which is a more accepted system in Sweden.The report states that IT-systems has major advantage against TN-systems. The reason is that potential earth fault currents in TN-S-systems might end up disconnecting the fuse or residual current breaker of affected distribution system. This issue doesn't exist in IT-systems where minor fault current is generated from isolation fault. Therefore the recommendation is to equip these medical areas with IT-systems and the associated insulation monitoring systems. This technical solution provides adequate safety for both personal and patients regarding to electrical safety.

Place, publisher, year, edition, pages
2015. , p. 30
Keywords [en]
IT-system, TN-system, isolation monitoring system, earth fault, selectivity, medical areas, electrical power systems
Keywords [sv]
IT-system, TN-system, isolationsövervakningssystem, jordfel, selektivitet, medicinska utrymmen, elektriska fördelningssystem
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-8187Local ID: XEL500OAI: oai:DiVA.org:hv-8187DiVA, id: diva2:855678
Subject / course
Electrotechnology
Supervisors
Examiners
Available from: 2015-09-25 Created: 2015-09-22 Last updated: 2015-09-28Bibliographically approved

Open Access in DiVA

fulltext(1896 kB)2637 downloads
File information
File name FULLTEXT01.pdfFile size 1896 kBChecksum SHA-512
f2c8e6d460a7a14a18dfe185ff010f5bcd2518384392bdb18f98b5333769f84c06a28465d6baf9e29f56a40d5066520b81d354fcc9fc99f0c29a6cce68eda25a
Type fulltextMimetype application/pdf

By organisation
Division of Computer, Electrical and Surveying Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 2637 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 754 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf