Provplan för validering av reläskyddmed Omicron CMC 356
University West, Department of Engineering Science, Division of Automation Systems.
University West, Department of Engineering Science, Division of Automation Systems.
2015 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
Test plan for validation of relay protection withOmicron CMC 356 (English)
Abstract [sv]

Vattenfall Eldistribution AB (Vattenfall) har ett intresse av att standardisera återkommande underhållsprovningar inom kontrollanläggning. Vattenfall kommer inom de närmsta åren att upphandla underhållsåttagandet vilket kan resultera i att flera olika aktörer, med blandad kompetens, kan åta sig underhållet i ett område. För att säkerställa provningen av reläskydd 

eftersträvas en provplan som eventuellt skulle underlätta underhållsprovningen på

mellanspänningsnivå. Detta examensarbete behandlar ämnet reläskydd och beskriver reläskyddets funktioner, testutrustning samt programvaran som används för att testa reläskyddets olika funktioner. Rapporten innehåller allmän teori kring reläskyddsfunktioner samt en beskrivande del som behandlar ABBs reläskydd REF620 med förklaring kring funktionerna och inställningarna i REF620.

De funktioner som valideras och förklaras i rapporten är överström, över- samt underspänning, frekvensskydd och jordfelsskydd. För att testa reläskyddets funktioner skapades en provplan i mjukvaran Omicron Test Universe 3.00. Detta program styr provinstrumentet Omicronen och kickar ut storheter i form av spänning och ström till reläskyddet, för att simulerar onormala tillstånd i elnätet. Simuleringen av ett onormalt elnät visar att reläskyddet uppnår de krav som ställs på gränsvärden för starttider, fördröjningstider samt vilket värde som reläskyddet ska startas vid. I de fall reläskyddet inte klarade testerna fördes en diskussion kring anledningar. Dessa anledningar kan vara de mekaniska reläerna i reläskyddet bidrar med en viss fördröjning samt att reläskyddet kan ha vissa förprogrammerade säkerhetsmarginaler som gör att skyddsfunktionerna reagerar snabbare respektive långsammare än väntat. Omicron CMC 356 är ett effektivt testinstrument som med den medföljande mjukvaran underlättar provningen. Det går enkelt att tillhandahålla felrapporter och resultat.

Abstract [en]

Vattenfall Eldistribution AB (Vattenfall) got an interest in standardising the reoccurring maintenance tests in the power. During the coming years Vattenfall will be having their maintenance work in the power monitoring facility out for procure which can result in several different actors with mixed skills may commit to the maintenance of a certain area. To ensure that the testing of relay protections will be performed the same way by all of the drafted maintenance staff Vattenfall wants a testing manual that the staff can follow. Vattenfall hopes that the manual will be of use for the staff to ease the testing on the medium voltage level. This thesis contains the subject safety relays and describes the relay functions, the testing equipment and the software associated whit the testing equipment. This thesis also contains theory regarding safety relays and some specific functions in the relay. There's also an explanation regarding the safety relay REF620 from ABB within the theory regarding the tested functions. The validated functions that are explained in the thesis are over and under current, over and under voltage, frequency protection and earth fault protection. The computer program from Test Universe 3.00 from Omicron was used for validating the functions. This program controls the testing equipment Omicron and sends the voltage and current quantities to the safety relay, the quantities are used to simulate faults in the distribution network. The simulation of the faulted network shows that the ABB REF620 safety relay meets the demands on the safety limits on the start and trigger values. In the few cases the safety relay didn't meet the requirements there were a discussion regarding the causes of the failed test.

A part of the issue could be that the mechanical relay inside the safety relay may cause some delay time, other reasons for the delay time may be due to preprogramed safety marginal that makes the safety relay act quicker or slower than expected. Despite some test failed due to the delay it's all in the valid range of the safety marginal. The Omicron CMC 356 in combination with the testing software is an effective tool for testing safety relays. In the software it's easy to access the error reports and results.

Place, publisher, year, edition, pages
2015. , p. 33
Keywords [en]
Relay protection, overcurrent, Short circuit, Earth fault, under voltage protection
Keywords [sv]
Reläskydd, Överströmskydd, jordfelsskydd, överspänningsskydd
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-8186Local ID: EXH300OAI: oai:DiVA.org:hv-8186DiVA, id: diva2:855667
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2015-09-25 Created: 2015-09-22 Last updated: 2015-12-22Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Automation Systems
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 848 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf