Identifiering av energiförluster i distributionsnät
University West, Department of Engineering Science, Division of Automation Systems.
2015 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Identification of energy losses in distribution grid (English)
Abstract [sv]

Energieffektivisering är en fråga som blir allt mer aktuell i dagens samhälle. Genom att spara på energi gynnas såväl miljö som ekonomi men för att kunna göra detta måste det först finnas kännedom om vilka energiförluster som finns. Syftet med detta arbete är att närmare identifiera de energiförluster som uppkommer i ett distributionsnät samt att undersöka hur förlusterna kan minskas.

Det valda mätområdet omfattar en utgående högspänningslinje med fyra nätstationer och sammanlagt 895 st. abonnenter varav en högspänningsabonnent. Genom mätningar med analysinstrument i områdets tre nätägda stationer beräknades transformatorförlusterna i respektive station. Vid mätningarna visade sig förlusterna bli negativa, vilket i verkligheten är omöjligt. Vid jämförelse mellan mätning med analysinstrument i station och insamlade värden från abonnenters mätare, visade sig förlusten bli orealistiskt stor. Undersökning av mätnoggrannhet för mätningar utförda i stationer visade att noggrannheten är mycket låg, så låg att det inte går att veta om även rimligt erhållna värden är korrekta eller inte. Även insamlade värden från abonnenters mätare visade sig vara mycket osäkra under korta tidsperioder. Troligen bidrar båda dessa källor till de felaktiga resultaten.

Då rimliga energiförluster inte har kunnat fås fram via mätningar med analysinstrument har dessa istället beräknats för perioder om ett år. Detta har gjorts med hjälp av uppmätt förbrukning från abonnenter samt teoretiska förlustvärden erhållna från tillverkarna av de undersökta objekten. För de tre transformatorerna i området jämfördes kostnaderna för energiförlusterna med vad motsvarande kostnad blir om moderna transformatorer installeras i deras ställe. Resultatet visar att ett utbyte till motsvarande storlek inte är ekonomiskt lönsamt. Besparingen i förlustkostnad är för låg i förhållande till kostnaden för transformatorerna. Förluster har även beräknats för ett urval av hög- och lågspänningskablar. Ingen jämförelse av förlustvärden mellan befintliga kablar och nya moderna genomfördes då värdena för dessa fanns vara ungefär lika stora.

Under mätningarna med analysinstrument mättes även övertonshalter av spänning och ström på lågspänningssidan i de tre stationerna. Resultatet visar att övertoner förekommer men var inom godkända gränsvärden för aktuella mätperioder.

Abstract [en]

Energy efficiency is an issue that is becoming more relevant in today's society. By saving energy both the environment and economy benefits, but in order to do this, information about the existing energy losses must first be known. The purpose of this work is to identify the energy losses that occur in a distribution grid, and explore how the losses can be reduced.

The selected measuring range covers one outgoing high voltage line, with four substations and a total of 895 customers of which one is a high voltage customer. Through measurements with power monitoring instruments transformer losses were calculated in the area's three substations. The losses proved to be negative, which in reality is impossible. When comparing between measurements made with power monitoring instruments in the stations and collected values from customer's meters, the loss proved to be unrealistically high. Investigation of the accuracy of the measurements performed in the stations showed that the accuracy is very low, so low that it cannot be certain if even reasonable values are accurate or not. Collected values from customer meters also proved to be very uncertain for shorter periods of time. Both these sources probably contribute to the faulty results.

When the resulting energy loss could not be obtained by measurements with power monitoring instruments these were instead calculated over a period of one year. This was done through measured energy consumption of customers and theoretical values of losses obtained from the manufacturers of the investigated components. For the three transformers in the area the costs of energy losses were compared with the corresponding value if modern transformers were installed in their place. The results show that an exchange of equivalent size is not economically profitable, the cost saving for the losses is to low relative to the cost of the transformers. Losses have also been calculated for a selection of high and low voltage cables. No comparison of loss values between the existing cables and new modern was carried out because the values for these were found to be approximately equal.

During the conducted measurements the harmonic levels of voltage and current on the low voltage side in the three stations were also measured. The result shows that harmonics occur but were within approved range during the periods of the conducted measurements.

Place, publisher, year, edition, pages
2015. , p. 51
Keywords [en]
Power, Energy, Losses, Measurement, Harmonics, Transformer, Distribution grid
Keywords [sv]
Effekt, Energi, Förluster, Mätning, Övertoner, Transformator, Distributionsnät
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-7472Local ID: EXC585OAI: oai:DiVA.org:hv-7472DiVA, id: diva2:798046
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2015-03-25 Created: 2015-03-25 Last updated: 2015-03-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Automation Systems
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 512 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf