Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Utredning av variablerna som påverkar storleken på brytspänningen i lindningskopplare
University West, Department of Engineering Science, Division of Automation Systems.
2015 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Investigation of the variables that affect the recovery voltage in tap-changers (English)
Abstract [sv]

Brytspänningen är den spänning som uppkommer när överkopplingsmotståndet i lindningskopplaren lämnar sitt föregående läge vid omkoppling. Storleken på brytspänningen i lindningskopplaren beror på hur stor läckinduktansen är. Är den inte känd så kan brytspänningen istället beräknas med hjälp av FEM-programmet ACE (internt ABB-program) i samband med Mathcad. I ACE beräknas först reaktanserna i p.u-enheter mellan lindningarna och hur stora de är beror på lindningslayouten. Det är tidskrävande att använda ACE och Mathcad och uppgiften är att utreda de parametrar som påverkar storleken på brytspänningen samt att ta fram en förenklad beräkning av densamma.

Genom simulering i ACE av en mängd olika lindningslayouter visar det sig snart att det är alltför många parametrar som påverkar reaktanserna. De förenklingar som trots det har tagits fram är lite för grova för att det ska vara pålitligt. Mathcad är än mer komplext med tunga beräkningar som inte är lätta att förenkla.

Arbetet har ändå gett mer kunskap om hur reaktanserna påverkas av geometrierna i lindningarna och kommer att vara till viss nytta, även om det inte gick att förenkla ACE- och Mathcadberäkningarna så som var tänkt.

Abstract [en]

The recovery voltage is the voltage that occur when the transition resistor in the tap-changer leaves its previous position during an operation cycle. The amplitude of the recovery voltage depends on the leakage inductance.

If the leakage inductance is unknown, the recovery voltage can instead be calculated using a FEM-program called ACE (internal ABB-program) in conjunction with Mathcad. First, the reactances between the windings are calculated in per unit (p.u) using ACE and they depend on the winding layout. It is time consuming to use ACE and Mathcad and the task has been to investigate the parameters that affects the recovery voltage and to develop a simplified calculation of it.

Through simulation using ACE of a number of different winding layouts one soon comes to the conclusion that there are simply too many parameters affecting the reactances. Although the simplified calculations that despite this has been developed, they soon prove to be too rough to be useful. Mathcad is even more complex with heavy calculations that are not easy to grasp.

However, this thesis has given more knowledge about the way the reactances are affected by the geometry of the windings, even though it was not possible to in a reasonable way simplify the calculation of ACE and Mathcad.

Place, publisher, year, edition, pages
2015. , p. 16
Keywords [en]
Tap-changer, recovery voltage, leakage inductance
Keywords [sv]
Lindningskopplare, brytspänning, läckinduktans
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-7467Local ID: EXC585OAI: oai:DiVA.org:hv-7467DiVA, id: diva2:798006
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2015-03-25 Created: 2015-03-25 Last updated: 2015-03-25Bibliographically approved

Open Access in DiVA

fulltext(631 kB)1094 downloads
File information
File name FULLTEXT01.pdfFile size 631 kBChecksum SHA-512
3f8f8bd7a734d41a003f2e7851c9a5c8b356910781215f8227a64e576f6307292c0aece91abb4873e782a3da3713308d85a85a45aed4467bb574b1aa8e49eb98
Type fulltextMimetype application/pdf

By organisation
Division of Automation Systems
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1094 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 879 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf