Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Undersökning av orsaker till komponenthaverier i uppsamlingsnätet till vindkraftparkerna Vettåsen och Mårtensklack
University West, Department of Engineering Science, Division of Computer and Electrical Engineering.
University West, Department of Engineering Science, Division of Computer and Electrical Engineering.
2014 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Investigation of the causes for component failures in the wind power plants Vettåsen and Mårtensklack (English)
Abstract [sv]

I detta examensarbete studeras spänningsvariationer och dess konsekvenser i Wallenstams uppsamlingsnät för två av deras vindkraftsparker Vettåsen och Mårtensklack i Ockelbo och Sandvikens kommun. Sedan idrifttagningen av de två parkerna i december 2011 har totalt sex haverier inträffat där spänningstransformatorer och ändavslut gått sönder. Då inga elkvalitetsmätningar utförts i samband med haveri kan ej exakt orsak fastställas. Mätningar i nätet som är utförda efter att haverierna inträffat påvisar inga tendenser på elkvalitetsstörningar som kan skada utrustningen. Däremot visar den att det förekommer lindriga halter av övertoner samt transienter i nätet. Då övertonsmätningar endast är gjorda till och med 50:e överton är en möjlig orsak till haverierna inverkan från övertoner av högre ordning. Faktorer som med stor sannolikhet kan avskrivas är bland annat åska, omkopplingar i nätet, fabrikationsfel samt installationsfel. En åtgärd för att motverka havererade ändavslut kan vara att använda avslut med geometrisk fältstyrning vilka är speciellt framtagna för att användas i nät med övertoner. Vidare kan ventilavledare installeras i Vettåsen och Mårtensklacks station för att skydda hela anläggningen mot transienter. För att kunna säkerställa bakomliggande orsaker till haverierna krävs det fortsatt arbete med elkvalitetsmätningar.

Abstract [en]

The purpose of this thesis is to investigate why the cable terminations and power transformers in Wallenstam’s wind power plants, at Vettåsen and Mårkensklack, have broken down six times since December 2011, which was when they were first put into service.

Power readings have been taken but there are no records for the times of the failures, which make it difficult to specify the failure source. However, from the readings that have been taken, there is nothing to indicate a cause for the failures. The transients are small and the proportions of harmonics are low. Since the instruments used to take the readings will only record up to 50th harmonics, a possible cause of failure could be high harmonics. Thunder storms, and cutovers in the power grid can probably be dismissed as sources of failure as well as manufacturing and installation faults.

One proposal to remedy cable termination failures is to use geometric terminations which have been developed for grids with harmonics. Also, to reduce transients in the systems, surge arresters could be installed at the Vettåsen and Mårtensklack stations to ensure that the power quality can be monitored. The power readings need to be continued to specify the failure source

Place, publisher, year, edition, pages
2014. , p. 30
Keywords [sv]
Vindkraftspark, elkvalitet, spänningstransformator, ändavslut, övertoner, transienter, haveri
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-6199Local ID: EXC585OAI: oai:DiVA.org:hv-6199DiVA, id: diva2:715521
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2014-05-05 Created: 2014-05-05 Last updated: 2015-12-22Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Computer and Electrical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 438 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf