Jämförelse av riktade reläskyddsfunktioner i impedansjordade nät
University West, Department of Engineering Science, Division of Computer and Electrical Engineering.
University West, Department of Engineering Science, Division of Computer and Electrical Engineering.
2014 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Comparison of directional relay functions in impedancegrounded network (English)
Abstract [sv]

Detta examensarbete beskriver hur olika nollpunktsmotstånd och resistanser i ett felställe påverkar nollföljdsströmmarna och nollföljdsspänningarna vid olika snedavstämningar i eldistributionsnätet. Eftersom snedavstämningarna i nätet påverkar om jordfelsskydden detekterar en jordslutning, genomförs en jämförelse mellan två olika jordfelsfunktioner, vinkelmätande funktion och admittansmätande funktion. Skillnaden mellan jordfels-funktionerna är att riktningen på jordslutningen och inställningarna för känsligheten sker på olika sätt. Syftet med rapporten är att redovisa för- respektive nackdelar med de båda jordfelsfunktionerna.

På grund av att luftledningar ersätts med bland annat markkabel, har de kapacitiva jordslutningsströmmarna ökat i fördelningsstationerna. De kapacitiva jordslutnings-strömmara måste kompenseras eftersom kapacitansen kan orsaka stora snedavstämningar i nätet. Vid för stora snedavstämningar blir nollföljdsspänningen och den resistiva nollföljdsströmmen för låga och jordfelsskydden kommer inte att detektera en eventuell jordslutning. Risken med detta är att ett överliggande reservskydd istället löser ut hela fördelningsstationen eller att jordslutningen inte bortkopplas alls.

Efter ideala simuleringar och olika provningar av ett jordfelsskydd i laboratoriemiljö, kan det konstateras att det inte är någon större skillnad mellan de båda jordfelsfunktioner. Det finns dock vissa avvikelser vid de experimentella provningarna av jordfelsskyddet. Avvikelserna beror bland annat på vilken jordfelsfunktion som testades, eftersom upplösningen på jordfelsskyddet ställdes olika. Vilken jordfelsfunktion som är den bättre i verkliga nät är svårt att konstatera eftersom sådana tester ej har genomförts i denna studie.

Målet med examensarbetet har uppfyllts eftersom författarna har kunnat redovisa för- och nackdelar med de båda jordfelsfunktionerna, även när skillnaden mellan dem var liten

Abstract [en]

This thesis describes how different values on a neutral grounding resistor and an uncompensated power distribution network affect the zero sequence current and the zero sequence voltage. If the neutral grounding reactor in the power distribution network is too overcompensated or undercompensated, the directional earth-fault relay may not work. The purpose of this study is to present the advantages and disadvantages of two different earth-fault functions. The two earth-fault functions that will be compared are an admittance-based earth-fault protection and a directional earth-fault protection with angle calculation between the zero sequence current and the zero sequence voltage.

The capacitive earth-fault currents have increased in the distribution stations because the overhead lines are replaced with underground cables. The capacitive current must be compensated since the capacitance can cause an overcompensated or an undercompensated network. An uncompensated distribution network may cause the zero sequence current and voltage becoming too low so that the earth-fault protections do not detect an earth-fault.

After the comparison of the two earth-fault functions it can be concluded that there is a minor difference between the both functions. There are some deviations in the test results conducted in a laboratory environment. It is not possible to state which one of the functions that is the most suitable to use in real power distribution networks, since no such tests have been conducted in this study.

The authors of this thesis have presented some advantages and disadvantages of the two earth-fault functions

Place, publisher, year, edition, pages
2014. , p. 46
Keywords [sv]
Reläskydd, jordfelsskydd, admittansfunktion, vinkelmätande funktion, symmetriska komponenter, snedavstämda nät
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-6039Local ID: EXC585OAI: oai:DiVA.org:hv-6039DiVA, id: diva2:704866
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2014-03-14 Created: 2014-03-13 Last updated: 2015-12-22Bibliographically approved

Open Access in DiVA

fulltext(2575 kB)8382 downloads
File information
File name FULLTEXT01.pdfFile size 2575 kBChecksum SHA-512
21151a1dd7889f9b424ad0ad0449bbcd21ded317f2c7c8901d1709fd8f98968ad0edfcc429178cfd3af2df7114528a47bec1c0a71debd4d8a8d0d588d4fc852d
Type fulltextMimetype application/pdf

By organisation
Division of Computer and Electrical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 8382 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 2347 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf