Driftoptimering av effektkondensatorbatterier och transformatorer på mottagningsstationer
University West, Department of Engineering Science.
2010 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesis
Abstract [sv]

Denna rapport innehåller en utredning av effektflöden på Uddevalla Energi Elnät AB:s mottagningsstationer och optimering av driftläggning för dess effektkondensatorbatterier och transformatorer.

Uddevalla Energi Elnät AB har sedan 30 år haft effektkondensatorbatterier inkopplade nästan hela året och dessa behöver av åldersskäl snart bytas ut. Uddevalla Energi Elnät AB har därför behov av nya rutiner för driftläggning av effektkondensatorbatterier efter det att Svenska Kraftnät och Vattenfall AB har infört nya regler för de reaktiva effektflödena i elnätet.

I utredningen om effektkondensatorbatterier har det gjorts en investeringskalkyl med tre alternativ för inköp. Alternativ 1 med central faskompensering på mottagningsstation, alternativ 2 med faskompensering på mottagningsstation kompletterat med faskompensering på abonnentstationer och alternativ 3 med lokal faskompensering på abonnentstationer.  Det framkom i utredningen att alternativ 2: Central faskompensering kompletterat med faskompensering på abonnentstationer är mest lämplig att genomföra.  

Det har tidigare konstaterats att det under delar av året har varit låg belastning på några av mottagningsstationernas transformatorer. Det har aldrig utretts om det är lönsamt att stänga av den ena transformatorn under hela eller delar av året.

I utredningen om driftläggning av transformatorerna på mottagningsstationerna har det beaktats tre alternativ. Ett alternativ innebär att en transformator körs i tomgång utan last och ett alternativ med en helt avstängd transformator. Det tredje alternativet är att inte göra någon förändring. I utredningen framkom det att det mest lämpliga är att inte göra någon förändring eftersom riskerna med avstängning är större än den ekonomiska vinsten på c:a 101000 SEK.

Abstract [en]

This report contains a study of power flows in Uddevalla Energi AB receiving stations and optimization of the operation control of its power capacitor batteries and transformers.

For the past thirty years, Uddevalla Energi AB has employed power capacitor batteries almost all year around and these need soon to be replaced due to ageing. Uddevalla Energi Elnät AB has a need for new procedures for the operation control of the power capacitor batteries following new regulations introduced by Svenska Kraftnät and Vattenfall AB for reactive power flows on the grid.

In the study of power capacitor batteries, there has been an investment calculation with three alternative purchase options. Option one is central phase compensation at the receiving station, option two is phase compensation at the receiving station supplemented with phase compensation at subscriber stations and option three is a local phase compensation at subscriber stations. The investment calculation shows that the second option: Central phase compensation supplemented with phase compensation at subscriber stations is the most favourable to implement.

It has previously been found that, during certain times of the year, there has been a low load on some of the transformers of the receiving stations. It has never been investigated if it is profitable to turn off one of the transformer for the entire, or part of the year.

In the investigation of the operation control of the transformers at the receiving stations, three alternatives have been considered. One alternative is that one transformer is in idle operation without load, the second alternative is that one transformer is completely turned off. The third alternative is to make no change. The study showed that the preferred alternative is to make no change, because the risks of turning off transformers are greater than the economic gain, that is approximately 101000 SEK.

Place, publisher, year, edition, pages
2010. , 26 p.
Keyword [en]
Power loss, Reactive power, Transformer, Operating effiency
Keyword [sv]
Effektförluster, Reaktiv effekt, Transformatorer, Driftoptimering
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-2543OAI: oai:DiVA.org:hv-2543DiVA: diva2:327814
Subject / course
Electrotechnology
Educational program
Elkraft
Uppsok
Technology
Supervisors
Examiners
Available from: 2010-07-01 Created: 2010-06-17 Last updated: 2015-12-22Bibliographically approved

Open Access in DiVA

fulltext(562 kB)1106 downloads
File information
File name FULLTEXT01.pdfFile size 562 kBChecksum SHA-512
fbf96d2e3cc66b2e7b5f43933e9fd8ce8299a4ec2ae1d288bc6acb3a1717b7ada087d9823e0c6a925aade8350608ef39ad26abee54133cb0d802ba8da7c84fed
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Gustafsson, Stig
By organisation
Department of Engineering Science
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 1106 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 638 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf