Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Resistiva nollföljdsströmmars påverkan på jordfelsskydd i impedansjordade nät
University West, Department of Engineering Science.
2024 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Resistive zero sequence currents impact on earth fault protection in impedance grounded grid (English)
Abstract [sv]

Nu för tiden kablifieras nätet, vilket innebär att allt fler luftledningar ersätts med markkabel, en följd av stormar som åstadkommit stora och långa avbrott i nätet. Egenskaperna i elnätet förändras på grund av kablifieringen och beräkningarna för reläskyddsinställningarna för de riktade jordströmsskyddet som görs idag behöver därför ses över om de fortfarande kan utföras på samma sätt som tidigare. Detta för att säkerställa korrekt och selektiv felbortkoppling i händelse av fel. I föreliggande rapport förklaras i förenklade drag hur resistiva nollföljdsströmmar rör sig i nätet och hur de mäts in av jordfelsskydd.

Ett fiktivt 22 kV nät har studerats och jordfel på två olika ledningar i detta nät analyseras och diskuteras. Beräkningar görs med olika storlekar på nollpunktsmotstånd samt olika höga resistiva nollföljdsbidrag från ledningarna vilket ger olika resistiva nollföljdsströmmar i nätet. Detta görs i både normaldrift och i reservdrift för att kunna studera vilka skillnader som faktiskt kan uppkomma. Diskussion sker om vad som hänt om hänsyn tagits till snedavstämning, obalans, vinkelfel och mätfel, vilket beräkningarna i detta arbete inte gör. Slutsatsen som dras av den utförda studien är att det är svårt att ställa in riktade jordströmsskydd samt nollpunktsspänningsskydd för att kunna säkerställa korrekt bortkoppling vid både normal- och reservdrift. Detta på grund av de olika resistiva nollföljdsströmmarna som uppkommer i nätet.

Abstract [en]

Today more and more overhead lines are replaced by underground cables as a result of storms which have caused major interruptions in the power grid. Because of the cabling, the characteristics of the power grid change and the calculations for the relay protection settings that are made today need to be reviewed if they still can be performed in the same way as before. This to ensure correct and selective fault disconnection. This report, in a simplified way, explains how resistive zero-sequence currents flow in the grid and how they are measured by earth fault protection.

A fictitious 22 kV grid has been studied and earth faults on two different cables in the grid are analyzed and discussed. Calculations are made with different sizes of the zero-point resistance resulting in different resistive zero-sequence currents in the grid. This is done both in normal operation and reserve power operation to be able to study differences that can occur. Discussions are made regarding misalignment, imbalance, angle error and measurement error, which have not been included in this work. The conclusion from the study performed is that it is difficult to parameterize a directional earth fault protection and a zero-point voltage protection correctly to be able to secure a correct disconnection in both normal and backup operation. This is because of the various resistive zero-sequence currents that arise in the grid. 

Place, publisher, year, edition, pages
2024. , p. 35
Keywords [en]
zero sequence, impact, earth fault
Keywords [sv]
nollföljdsström, påverkan, jordfelsskydd, nät, impedansjordade
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-21439Local ID: EXE512OAI: oai:DiVA.org:hv-21439DiVA, id: diva2:1847532
Subject / course
Electrotechnology
Educational program
Elektroingenjör - Elkraft
Supervisors
Examiners
Available from: 2024-04-08 Created: 2024-03-28 Last updated: 2024-04-22Bibliographically approved

Open Access in DiVA

fulltext(2741 kB)54 downloads
File information
File name FULLTEXT01.pdfFile size 2741 kBChecksum SHA-512
d6453698ec02b42eb031b5dfd7bb32ed1c7eb0584eb3edc6f3fb71da58ea632150a5bf05d7caa97fb8b76745988675ba9d5ea7b3aaa0c46ed3f86ab315d37804
Type fulltextMimetype application/pdf

By organisation
Department of Engineering Science
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 54 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 169 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf