Selektivitet i mindre nätstationer
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
2000 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Protection coordination in smaller secondary substations (English)
Abstract [sv]

Uddevalla Energi Elnät AB (UEE) är ett elnätsföretag som är dotterbolag i Uddevalla Energi AB och som har ensamrätt att bygga och driva elnät inom sin koncessionsgräns. Inom nätet finns över 500 nätstationer. Elnätet är ca 170 mil långt och sträcker sig från Ljungskile i söder till Uddevalla i norr och Öresjö i öst. 

UEE har ett idag gällande styrdokument kring användningsområdet av högeffektsäkringar som är baserade på transformatorns märkeffekt. Styrdokumenten beskriver och förtydligar drift- och underhållsavdelningens krav och önskemål på elanläggningar både vid ny- och ombyggnation. 

Syftet med rapporten har varit att ta fram ett förslag till uppdatering av styrande dokument. Ett lösningsförslag har tagits fram kring de av UEE identifierade felen kring oselektiv utlösning av total- och delområdessäkringar beroende på feltyp i underliggande nät. I rapporten rekommenderas val av största gruppsäkring för utgående grupper vid scenario med och utan överlastsskydd av transformatorn. Rapporten bidrar med underlag till UEE att uppdatera de styrande dokumenten för framtida projekt vid ny- och ombyggnation av nätstationer.

Studien har utformats som en systemstudie där modellering har gjorts av tre typnätstationer med transformatorstorlekarna 100 kVA, 200 kVA och 315 kVA. Dimensionerande strömmar har beräknats för att ta fram passande säkringar. Förutsättningarna för de tre modellerna har beräknats fram manuellt och har hämtats från UEE:s NIS program Digpro. Detta har bidragit till en möjlighet att kunna jämföra manuella beräkningar med värden hämtade från NIS programmet.

Respektive modellstations resultat visar att användandet av delområdessäkringar är det bästa alternativet som kortslutningsskydd i samtliga modellstationer. Baserat på resultatet från studien ges även rekommendation av storleksval till säkringar som överlastskydd för transformatorn samt största gruppsäkring för utgående ledningar.

Abstract [en]

Uddevalla Energi Elnät AB (UEE) is a distribution system operator which is a subsidiary of Uddevalla Energi AB. UEE has the right to build and operate distribution systems within its concession limit. Within the grid there are more than 500 secondary substations. The grid is about 170 km long from Ljungskile in the south to Uddevalla in the north and Öresjö in the east. 

UEE has a governing document for the use of high-power fuses in relation to the rated power of the transformer. The document describes and clarifies the operations and maintenance department's requirements and wishes for electrical installations for both new and remodeling.

The purpose of this report has been to produce a proposal for an update of the governing documents. A solution proposal has been developed regarding the errors identified by the UEE regarding non-selective triggering of total and sub-area fuses depending on the type of error in the underlying network. In addition, recommendations regarding the selection of the largest group fuse for outgoing groups in scenarios with and without overload protection of the transformer. The report provides UEE with basis for future projects for new and rebuilding of substations.

The study has been designed as a system study where modeling has been done of three type secondary substations with transformer sizes 100 kVA, 200 kVA and 315 kVA respectively. Dimensioning currents have been calculated to produce suitable fuses. The conditions for the three models have been calculated manually and have been retrieved from the UEE's NIS program Digpro. This has contributed to the possibility of being able to compare manual calculations with calculations made in the NIS program.

The results of each model station show that the use of sub-area fuses is the best alternative as short-circuit protection in all models. The result also gives a recommendation of size choice for fuses as overload protection for the transformer and the largest group fuse for outgoing lines

Place, publisher, year, edition, pages
2000. , p. 63
Keywords [sv]
Elnät, styrdokument
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-18149Local ID: EXE511OAI: oai:DiVA.org:hv-18149DiVA, id: diva2:1637198
Subject / course
Electrotechnology
Educational program
Elektroingenjör - Elkraft
Supervisors
Examiners
Available from: 2022-02-18 Created: 2022-02-12 Last updated: 2022-02-18Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 149 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf