Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Teknisk specifikation av transformatorer för mottagarstation M5 samt transformatorskyddsfilosofi
University West, Department of Engineering Science, Division of Subtractive and Additive Manufacturing.
University West, Department of Engineering Science, Division of Subtractive and Additive Manufacturing.
2021 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Technical specification of transformers for sub-station M5 with transformer protection philosophy (English)
Abstract [sv]

Uddevalla Energi Elnät har för avsikt att investera i en ny mottagarstation som ska ersätta mottagarstation M5. Stationen har två stycken 40/10 kV oljeisolerade transformatorer på 16 respektive 20 MVA där den äldsta transformatorn är ifrån 1969. Underlag för en teknisk specifikation tas fram vilket innebär att olika val för transformatorn specificeras och utvärderas för att sedan kunna lämnas ut på anbud. Kortslutningsimpedans, vektorgrupp och isolationstyp är några av faktorerna som ska specificeras i en teknisk specifikation. Transformatorns isolationstyp avgör i vilken miljö och klimat den kan placeras. Isolationstypen styr också förmågan till att med hjälp av fläktar höja märkeffekten och möjligheten att drivas med en viss överlast. Oljeisolation är den isolationstyp som är mer kapabel till att utstå överlast och klarar svårare miljö sett till fukt och väta. Dock finns fördelar med torrisolerad transformator, bland annat miljöaspekten och förenklad uppställningsplats. I aktuellt fördelningsområde för station M5 är Uddevalla Kommun i en expansiv fas och framtida lastutveckling är svår att förutspå. Uddevalla Energi Elnät bygger fördelningsstationer enligt enkelfelskriteriet och med två redundanta parallella transformatorer. En transformator ska ha möjlighet att driva en hel stations last om en av transformatorerna fallerar. Detta gör att det i rapporten ges förslag på två 20 MVA-oljeisolerade transformatorer för framtida nybyggnation av M5 för att ha transformatorer som kan klara av en eventuell hög-last dag då en transformator ej är driftduglig. Det finns möjlighet att höja märkeffekten på transformatorerna via fläktar till 25 MVA om belastningen för stationen skulle öka nämnvärt efter installation och i drifttagning av transformatorerna. Elnätsbolag använder sig av tekniska riktlinjer för att ställa krav på reläskydd. Det anges vilka funktioner som ska ingå och hur inställningsmöjligheter ser ut för reläskydd. I examensarbetet redovisas hur några stora elnätsbolag ställer krav på sina reläskydd för transformatorer och vilka funktioner som ska ingå. En jämförelse görs mellan dessa bolag och Uddevalla Energi för att se vilka likheter och skillnader Uddevalla Energis utformning av reläskydd för krafttransformatorer har mot de övriga nämnda i rapporten. Slutsatsen dras att majoriteten funktioner är gemensamma men ett mindre antal avvikelser mellan bolagen finns.

Abstract [en]

Uddevalla Energi Elnät has the intention to invest in a new sub-station that is going to replace the existing sub-station M5. The sub-station is equipped with two 40/10 kV oil isolatedtransformers with rated power of 16 MVA and 20 MVA, the oldest transformer of the two is from 1969. A basis for a technical specification is produced, which means that different choices affecting the transformers shall be specified and valued. Short-circuit impedance, vector group and insulation type are some of the factors to be specified in a technical specification. The insulation type of the transformer decides which environment and climate the transformer can be placed in. The insulation type also decides the ability to rate up the transformer and withstand overload. Oil insulation is the insulation type that has the greater capability to withstand overload and cope with tough climate such as moisture. Even though there are pros with dry insulated transformer such as environmental profits and simplifiedstation-requirements.In the area of the existing sub-station M5 Uddevalla kommun is in an expansive phase and the load development for the future is hard to determine. Uddevalla Energi Elnät build substations according to simple-fault criteria and with two redundant parallel transformers. One of the two transformers should be able to operate with the total load of the sub-station if the other one fail to maintain in operational mode. Therefore, in this report a proposal of two20 MVA oil insulated transformers is given for the future construction of the new M5 tohave the ability to operate on a high-load day with one transformer out of operation. It ispossible to rate up the transformers with fans to 25 MVA if the load on the station would increase in the future significantly from the day of installation. Power grid companies use technical guidelines that explains their requirement for relay protections. The guideline specifies all the functions and settings that need to be included in the relay protection. The thesis describes how some of the larger power grid companies in Sweden have technical guidelines for relay protection and power transformers and what demands these guidelines have on functions and settings for the relay protections. Acomparison between the power grid companies that are mentioned in the thesis and Uddevalla Energi have been made that analyses the similarities and differences in the technical guidelines for relay protection and power transformer. The conclusion has been made that the majority of the functions are the same but there is a small difference between the companies in some areas of the relay protections.

Place, publisher, year, edition, pages
2021. , p. 52
Keywords [sv]
Elnät, mottagarstation
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-16302Local ID: EXE511OAI: oai:DiVA.org:hv-16302DiVA, id: diva2:1529739
Subject / course
Electrotechnology
Educational program
Högskoletekniker, elkraft
Supervisors
Examiners
Available from: 2021-02-23 Created: 2021-02-19 Last updated: 2021-02-23Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Subtractive and Additive Manufacturing
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 298 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf