Utförande och dimensionering av jordning i inomhusställverk upp till 145 kV
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
2019 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Design and inmplementation of grounding for indoor substations up to 145 kV (English)
Abstract [sv]

Rapporten är skriven som en systemstudie där syftet är att genom kvalitativa studier av befintliga krav och standarder säkerställa att Oteras Ratel AB:s konstruktionsarbete av jordningar i ställverk uppfyller dagens krav. Problemet är att det krävs en djupare bakomliggande förståelse för att kunna tillämpa gällande standard för dimensionering och utförande av jordningar och dessutom måste kraven på jordningssystem fastställas så att ett standardiserat arbetssätt kan utformas utifrån detta.

Rapporten går först övergripande igenom den teori och de begrepp som är nödvändiga för konstruktörens beslut. Teorin är insamlad från studier av föreskrifter, standarder, handböcker, rapporter och intervjuer. Teorin innefattar ämnen som jordfelsströmmar, dimensionering av jordledare och elektroder, jordpotentialstegring och beröringsspänning samt jordtag. Med hjälp av detta beräknas ett testfall där teorin appliceras på ett verkligt fall utgående från verkliga data.

Sedan diskuteras vikten av ett korrekt konstruerat jordningssystem och att konsekvensen av inkorrekt dimensionering är att felströmmen kan ta fel väg till jord. Rapportens teoridel och testfall diskuteras och sätts in i ett bredare sammanhang. Trots att en djupare förståelse om gällande standard ges i rapporten har inget standardiserat arbetssätt fastställts utan beslut måste fattas från fall till fall och vara bottnade i fakta. Resultatet i testfallet ifrågasätts då bakomliggande data inte är tillförlitlig vilket påverkar exemplets utfall.

I rapportens slutsats lyfts resultat och rekommendationer fram. Rapporten lyckas bryta ner arbetsgången och de begrepp som används vid konstruktion av jordning från svensk standard. Kraven på nivån av farliga spänningar har fastställts och rapportens huvudsakliga syfte är uppnått. Förslag till vidare arbete ges i form av djupdykning i de ämnen rörande jordning denna rapport avgränsar sig från som EMC-kompabilitet och åskskydd. Det går även att fortsätta arbetet genom att ytterligare studera strömdelning och mätning.

Abstract [en]

This report is written as a system study with the purpose of ensuring, through studies of existing knowledge, that Otera Ratel AB's construction regarding grounding in substations is up to par with today's standards. The challenge is that in-depth knowledge is required to understand and apply existing implementation and design standards for construction of grounding systems. Additionally, the requirements regarding safe voltage levels must be laid down so a standardized workplan based on that can be formed.

The report processes the overall theories and concepts which are necessary for the contractor’s decisions. Theory is collected from studies of regulations, standards, handbooks, reports and interviews. The theories treat subjects such as: earth fault currents, earthing conductors, earthing electrodes, earth potential rise, and touch voltage. These theories are subsequently applied to an example based on real data.

Thereafter, a discussion about the importance of a correct executed grounding system follows. The consequence of an incorrect designed system could be fault currents which take the wrong path to ground. The theory section and example case are both also discussed and inserted into a broader context. Despite the extensive knowledge of the standard provided in the report no standardized workplan can be determined. The decisions must be made on a case-by-case basis relying on case specific facts. The validity of the example case can be called in question since data is missing which affects the result of the example.

The report concludes by presenting the results and recommendations on how to scrutinize the standard and its concepts regarding successful grounding. The voltage requirements are also determined and hence the aim of the report is achieved.

Proposals for continued work include the themes which this report neglects but which are in some way connected to grounding, like EMC compatibility and lightning conductors. Furthermore, fault current splitting and methods for measurements are areas in which extra insight is needed.

Place, publisher, year, edition, pages
2019. , p. 40
Keywords [sv]
Kvalitetssäkring, ställverk
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-13580Local ID: EXE511OAI: oai:DiVA.org:hv-13580DiVA, id: diva2:1290683
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2019-02-25 Created: 2019-02-21 Last updated: 2019-02-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 543 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf