Differences in whole body measurements by DXA-scanning using two Lunar DPX-L machines
Show others and affiliations
1999 (English)In: International journal of obesity and related metabolic disorders : journal of the International Association for the Study of Obesity, ISSN 0307-0565, Vol. 23, no 7, p. 764-70Article in journal (Refereed) Published
Abstract [en]

OBJECTIVE: To compare bone mineral and body composition results of two dual-energy X-ray absorptiometry (DXA) instruments from the same manufacturer.

SETTINGS: The Medical departments of Sahlgrenska University Hospital, Göteborg and University Hospital, Uppsala, Sweden.

DESIGN: Unique aluminium spine phantoms (Phant A and B) delivered with each DXA machine (DXA-A and DXA-B) were cross-checked on the other machine by using the 'AP spine mode'. Eight adolescents were examined on both instruments within 5 h to ascertain total body variables by using standard, as well as extended, modes of analysis. All these double-examinations were undertaken on two occasions, before and after exchange of a detector on the DXA-B.

SUBJECTS: Four males and four females aged 15.4-19.2 y with normal body weights, were examined on both occasions. On each occasion, the first examination was performed in Göteborg on four individuals and in Uppsala on four individuals.

RESULTS: On the first occasion the phantom measurements resulted in much lower bone mineral density (BMD) values on the DXA-B than on the DXA-A. Later it was detected that a so-called R-value and the corresponding '%-fat' value were out of range on the DXA-B. After exchange of detector, the difference in phantom BMD-values between the two machines had diminished. On the first occasion in vivo BMD values were lowest on the DXA-B (P < 0.01), while on the second occasion they were significantly lower on the DXA-A (P < 0.05). Soft tissue differences were greater after detector exchange and as compared to DXA-A, DXA-B underestimated body fat by 3.5 kg (13.2 vs 9.7 kg, P < 0.001) and overestimated lean tissue mass by 3.8 kg (47.1 vs 50.9 kg, P < 0.001) on the second occasion.

CONCLUSIONS: The differences in results between two apparently identical Lunar DPX-L machines were not acceptable. In multicenter studies, it may be necessary to standardise results of participating machines into results of one machine by means of regression equations obtained by examining subsamples of individuals on one master machine and other participating instruments.

Place, publisher, year, edition, pages
1999. Vol. 23, no 7, p. 764-70
Identifiers
URN: urn:nbn:se:hv:diva-13316DOI: 10.1038/sj.ijo.0800905PubMedID: 10454112OAI: oai:DiVA.org:hv-13316DiVA, id: diva2:1273790
Note

Professor Gösta Samuelson samlade trycksaker; 182

Available from: 2018-12-21 Created: 2018-12-21 Last updated: 2019-04-17Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records BETA

Samuelson, Gösta

Search in DiVA

By author/editor
Samuelson, Gösta

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf