Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Larmanalys för Vattenfall Vattenkrafts produktionsanläggningar längs Göta Älv
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
2018 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Incident analysis of Vattenfall Vattenkraft hydro power facilities in the Göta river (English)
Abstract [sv]

Vattenfall Vattenkraft AB äger 57 storskaliga vattenkraftanläggningar där den installerade effekten överstiger 10 MW. Detta arbete berör larm och dess hantering i de fyra anläggningarna längs Göta älv. Rapporten analyserar larm och utryckningar från åren 2014– 2017 samt även själva larm- och kontrollsystemen, i syfte att identifiera möjliga förbättringsområden. Larmen sorteras efter feltyp, åtgärd, anläggning och säsong. De flesta larmen utgår från turbin och generatoranläggningar och handlar om onormala nivåer eller temperaturer. Sommar- och vintertid orsakar flest larm beroende på älvens varierande vattentemperatur och flöde. De fyra anläggningarna har ungefär samma antal utryckningar vilket är intressant då de varierar stort i ålder. Analysen identifierar inga återkommande fel som inte redan är kända av företaget men författarna rekommenderar att en utredning görs om installation av ålfilter till Lilla Edets kylvattenpumpar. Larmen genereras i anläggningarna och skickas till driftcentralen i Bispgården utanför Sundsvall där operatören ringer upp vakthavande maskinist. Denne måste sedan åka till anläggningen för att på stationsdatorn få detaljerad information om larmets orsak. Rapporten undersöker möjligheten att ge vakthavande tillgång till information från stationsdatorn via VPN, vilket är möjligt att implementera men skulle kräva en noggrann genomgång av vad en sådan funktionalitet skulle innebära för säkerheten. Vidare har larmens beskaffenhet undersökts, dessa är om- och utbyggda efter hand och det saknas en bra överblick. Författarna rekommenderar här en genomgång av larmlistorna och larmens prioritet. Slutligen föreslås en mer kvalitativ inriktning på framtida studier av larmhanteringen.

Abstract [en]

Vattenfall Vattenkraft AB owns 57 large scale hydro power plants in Sweden with installed power exceeding 10 MW. The study relates to four of the plants located along Göta river. This report analyzes incidents and the related remedial actions that have occurred during the period 2014 – 2017 as well as the alarm and control systems with the aim to identify potential improvements. The incidents are categorized by error, what actions have been undertaken to correct the issue, plant and season. The incidents have predominately originated in the turbine and generator facilities and have been caused by abnormal levels or temperatures. During summer and winter time, this is mainly due to variation in temperature and flow in the river. The four plants have caused a similar amount of alarms, which is interesting as there is a large variation in age. The analysis does not identify any reoccurring issues which were previously unknown to the company, but the authors recommends that an investigation is conducted to assess if eel screens should be installed for the cooling pumps of Lilla Edet. The alarms are generated in the plants and are sent to the control facility in Bispgården near Sundsvall, where the operator calls the local engineer on duty in Trollhättan. The engineer subsequently goes to the plant to access detailed information on the incidents from the local computers. This report examines the possibility to provide the engineer on duty with detailed information from the plant computer via VPN. This would be possible to implement but would require a detailed assessment of the security implications. The status of the alarm system have also been assessed as it have been modified and extended retroactively, and there is currently no comprehensive overview. The conclusion is that a review of the list of incident codes and their priority is recommended.

Place, publisher, year, edition, pages
2018. , p. 32
Keywords [sv]
Vattenkraft, elkraft
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-12785Local ID: EXH300OAI: oai:DiVA.org:hv-12785DiVA, id: diva2:1232351
External cooperation
Vattenfall Vattenkraft AB
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2018-07-24 Created: 2018-07-11 Last updated: 2018-07-26Bibliographically approved

Open Access in DiVA

fulltext(1923 kB)3 downloads
File information
File name FULLTEXT01.pdfFile size 1923 kBChecksum SHA-512
55690a9c166ffa550ef17ea6722bd913a5e089eb32f4c8db0cf48027a936cc7a286e7485fe3292aee9bd9ecdb618cab9bcfe5a129118a659495a9b462e92bc90
Type fulltextMimetype application/pdf

By organisation
Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 3 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 12 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf