Undersökning av resistansvärden i brytare och frånskiljare
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
University West, Department of Engineering Science, Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering.
2017 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Examination of resistance values in circuit breakers and disconnectors (English)
Abstract [sv]

Idag utförs underhåll med förutbestämda tidsintervall. Vattenfall Eldistribution vill utreda möjligheten att istället utföra ett förebyggande och mer proaktivt underhåll baserat på tillståndet i anläggningen. Därför arbetar Eldistribution på att ta fram ett Anläggningshälsoindex (AHI). Med hjälp av detta vill Eldistribution optimera underhållsplaneringen. Ett AHI består av ett antal parametrar som samlas in vid inspektion av anläggningarna. Övergångsresistansen i brytare och frånskiljare kan vara en av dessa parametrar. Brytare används i högspänningsnätet för att bryta alla sorters felströmmar som kan uppstå. De kan även användas för att göra omkopplingar i nätet vid arbete. Frånskiljaren är en apparat som används för att få ett tydligt visuellt brytställe. Men på grund av sin konstruktion kan den inte bryta strömmar utan endast bryta spänning.  Examensarbetet har genomförts både som teoretisk studie av brytare och frånskiljare tillsammans med fältstudie vid provning innan drifttagning av brytare. Ett antal intervjuer med sakkunniga inom området genomfördes också. Arbetet visar att det finns möjlighet att använda resistans i brytare som en av parametrarna för förebyggande underhåll. Men för att kunna använda resistansen i brytare som en av parametrarna krävs framtagning av tydliga gränsvärden.   

Abstract [en]

Today, maintenance is performed at predetermined time intervals. Eldistribution wants to investigate the possibility of performing a preventive and more proactive maintenance instead based on the state of the asset. Therefore, Eldistribution is developing an Anläggningshälsoindex (AHI). With this, Eldistribution wants to optimize maintenance planning. An AHI consists of a number of parameters collected when inspecting the asset. The resistance in circuit breakers and disconnectors can be one of these parameters. Circuit breakers are used in the high voltage grid to break all kinds of fault currents that may occur. They can also be used to make changes in the grid during work. Disconnector is a device used to get a clear visual breakpoint. Due to its construction it can’t break currents but it can break voltage. The thesis has been carried out both as theoretical study of circuit breakers and disconnectors together with a field study during testing before operation of circuit breakers. A number of intreerviews with experts in the field has also been carried out. The thesis shows that there is a possibility of using resistance in circuit breakers as one of the preventive maintenance parameters. However, in order to be able to use the resistance of the circuit breakers as one of the parameters, it is necessary to produce clear limit values.

Place, publisher, year, edition, pages
2017. , p. 32
Keywords [sv]
Eldistribution, underhåll
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-11624Local ID: EXH300OAI: oai:DiVA.org:hv-11624DiVA, id: diva2:1143673
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2017-10-02 Created: 2017-09-22 Last updated: 2017-10-07Bibliographically approved

Open Access in DiVA

fulltext(1558 kB)3306 downloads
File information
File name FULLTEXT01.pdfFile size 1558 kBChecksum SHA-512
e5da4bfbddd5d50c2d69cba6b0ff34eb9c2e67a6610b1b28ff2f9fa1cd724609463e825bd5c1d5bbd1c309a5d7cc203c3c936be5b5a3d0a02d2c57cc2172923e
Type fulltextMimetype application/pdf

By organisation
Division of Industrial Engineering and Management, Electrical- and Mechanical Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 3306 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 261 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf