Analys av övertoner i Akzo Nobels anläggning i Bohus
University West, Department of Engineering Science, Division of Computer, Electrical and Surveying Engineering.
University West, Department of Engineering Science, Division of Computer, Electrical and Surveying Engineering.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Analysis of harmonics in Akzo Nobels facility in Bohus (English)
Abstract [sv]

Denna studie ger en allmän beskrivning om vad elkvalitet och övertoner är. Här diskuteras även de problem och de störningar som uppstår vid uppkomsten av övertoner samt på vilka sätt dessa övertoner uppkommer i elnätet. Rapporten diskuterar även eventuella åtgärder samt beräkningsmetoder för att sammanställa dessa övertoner. EMC, elektromagnetisk kompatibilitet visar apparaters förmåga att samspela med varandra utan att påverka varandra. Elkvalitet är ett begrepp som beskriver olika mätbara kriterier på hur man bedömer en elleverans med avseende på dess kvalitet. Övertoner uppstår på grund av olinjära laster som ansluts till elnätet och som har på den senaste tiden uppmärksammats eftersom halterna har ökat. Övertoner skapas av olinjära elektriska belastningar så som switchade nätaggregat, lågenergilampor, svetsutrustningar etc.

Hos dessa olinjära laster blir lastströmmen distorderad och då uppstår övertoner i strömmen som i sin tur ger upphov till spänningsövertoner. Vid mätning av övertoner används uttrycket THD. THD (Total Harmonic Distortion) är ett uttryck för övertonshalten och kan beräknas för både strömövertoner samt spänningsövertoner. Delar av Akzo Nobels elnät uppmättes med ett elkvalitetsinstrument för att undersöka övertonshalten i både spänning och ström. Mätningarna utfördes på olika frekvensomriktare i anläggningens lågspänningsnät. Slutsatsen av mätningarna är att trots att man har tendenser till för höga övertonshalter i strömmen, är halten av spänningsövertonshalter normala och risken för skador på maskiner och annan utrustning på grund av övertoner är låg. Vårt förslag på eventuella åtgärder är att man installerar ett övertonsfilter om man ändå önskar minska halten av övertoner. Förslag på ytterligare ett arbete är att göra motsvarande mätningar på högspänningssidan i anläggningen med en mätutrustning som klarar av att mäta högre strömmar och spänningsnivåer.

Abstract [en]

This study deals with the general description about power quality harmonics. It also describes the problems and the overload that emerge during the occurrence of harmonics and their origin in the powerline. EMC, Electromagnetic Compatibility indicates how devices can co-operate without affecting or causing disruption to each other. Power quality is a phenomenon that describes different criteria about how to determine the electricity supply based on its technical quality. When talking about harmonics one talk about non-linear loads that occur in Swedish power network and has gained more attention through the years because of the increase in the levels. Harmonics origins from non-linear electrical equipment such as loads (equipment that consumers use), generation of electricity (production of power at e.g. windmill) and powerline (in transformers). During the non-linear loads the current load becomes non-sinusoidal which result in harmonics distortion that leads to a drop in the voltage. The consequence of this phenomena is that it occurs harmonics in the voltage. This means that the curve of the current load is distinguished from the normal sinusoidal curve based on the frequency and the amplitude. THD (Total Harmonic Distortion) is an indication of the harmonics distortion and can be calculated to determine the distortion in both the current and the voltage.

Akzo Nobel’s power line was studied to analyze the harmonics distortion for both the current and the voltage through different procedures on different frequency converters. The measurements were done on the low voltage line. The conclusion was that though the current showed high levels of the harmonics distortion which could be excluded because of the low levels of the harmonics distortion in the voltage which were stable and normal, which indicates that there is probably no damage done to the equipment and machines. Suggestions on certain solutions is that an installation of a special filter could be done to be able to reduce the levels of harmonics. Recommendations on further studies is to make more measurements but with equipment that can handle measurements on higher currents - and voltage levels where you can study the high voltage line instead.

Place, publisher, year, edition, pages
2017. , p. 37
Keywords [sv]
Elkvalitet, störningar, övertoner
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-10889Local ID: EXM505OAI: oai:DiVA.org:hv-10889DiVA, id: diva2:1083984
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2017-03-23 Created: 2017-03-23 Last updated: 2017-03-23Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Computer, Electrical and Surveying Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 229 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf