Planned maintenance
A system upgrade is planned for 24/9-2024, at 12:00-14:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Utvärdering av möjligheter för semiautomatisk reläskyddsprovning med Omicron CMC 356
University West, Department of Engineering Science, Division of Computer, Electrical and Surveying Engineering.
University West, Department of Engineering Science, Division of Computer, Electrical and Surveying Engineering.
2017 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
Evaluation of possibilities for semiautomatic relay protection testing with Omicron CMC 356 (English)
Abstract [sv]

När energiföretag upphandlar underhållsansvaret för stationer och anläggningar kan det leda till att anläggningarna provas av olika entreprenörer. För att uppnå en mer enhetlig provning av reläskydden bör de provas på samma sätt vid varje provningstillfälle. Reläskyddsprovning sker idag av erfaren personal och kan då till viss del provas på olika sätt då det saknas ett enhetligt sätt att prova skydden på. Detta leder även till att kunskapen för hur provning sker finns hos ett begränsat antal individer inom företaget.

Anledningen till att arbetet utförts är att uppdragsgivaren vill undersöka om reläskyddsprovning kan utföras på ett mer enhetligt sätt för att erhålla jämförbara resultat och minimera antalet misstag under provningen på grund av den mänskliga faktorn. Med Omicron CMC 356 och dess tillhörande mjukvara finns möjlighet att programmera vilka tester som ska genomföras och spara dessa för att sedan ta med dem och testa i stationen. Denna rapport är utförd som ett pilotprojekt med provning av en station med en Omicron CMC 356 för att möjliggöra för uppdragsgivaren att se hur Omicron CMC 356 skulle kunna implementeras i underhållsprovningen av reläskydd.

Inledningsvis behandlas de reläskyddsfunktioner som examensarbetet innefattar teoretiskt. Vidare finns en teoretisk genomgång av hur reläskyddet hanterar de olika felen, vilka begränsningar som finns samt vilken noggrannhet skyddet har för de olika funktionerna. Examensarbetet begränsar sig av tidsskäl till funktionerna: överströmsskydd, överspänningsskydd, underspänningsskydd, underimpedansskydd, differentialskydd, underfrekvensskydd och överfrekvensskydd. Rapporten innehåller även en praktisk del där provning av reläskydd har genomförts i en vattenkraftsstation. De testmoduler i Omicrons mjukvara: "Test Universe 3.10" som används för att testa de olika funktionerna och hur de programmeras kommer grundligt beskrivas i rapporten samt hur provningsprogrammets funktioner har programmerats.

Arbetets slutsats blev att många skyddsfunktioner går att prova automatiskt. En avvägning av ekonomi kontra kvalitet måste dock göras då det innebär ett stort introduktionsarbete att programmera provplaner för samtliga stationer som skall testas.

Abstract [en]

When energy companies undertake the maintenance responsibility for their power plants and facilities the protection systems may be tested by different contractors. As a result, the testing procedures may differ between facilities. In order to achieve a more similar testing of the protection relays they should be tested the same way every time. Testing of relays are usually performed by experienced personnel that may employ in slightly different ways of testing due to the lack of one which is standardized. This leads to a situation where the knowledge within this area of work stays in the minds of only a few employees of the company.

The reason for this project to be made is the employers wishes to investigate if the testing of relays can be performed in a more similar way in order to achieve comparable results and to minimize the risk of mistakes made during the testing.

With Omicron CMC 356 and the associated software "Test Universe 3.10" it is possible to program tests in advance and bring to the station and implement the prepared tests. This report is performed as a pilot project to show the client how the tests can be programmed and how Omicron might be implemented in the maintenance testing of their relay protection.

The report begins with a theoretical review of the functions that the thesis comprises. The construction of the relay with the principles it uses are explored, the limits and accuracy for the measurements are also reviewed. The thesis is because of time constraints limited to testing the functions: overcurrent, overvoltage, undervoltage, underimpedance, as well as differential and frequency protection. The thesis also contains a practical part in which testing of the relays was completed in a hydropower plant. Omicron CMC356 was the testing equipment used along with the related software "Test Universe 3.10", where the testing functions were programmed. The modules used for testing the relay functions are described along with the essential parts needed to test the functions that the thesis comprises.

The conclusion of the thesis is that several of the functions needed can be performed automatically. A decision has to be made about the balance between economy and quality because of the initial work that have to be made to program every station that is meant to be tested in this way.

Place, publisher, year, edition, pages
2017. , p. 60
Keywords [sv]
Energiföretag, underhåll, ansvar
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-10782Local ID: EXM505OAI: oai:DiVA.org:hv-10782DiVA, id: diva2:1079004
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2017-03-13 Created: 2017-03-07 Last updated: 2017-03-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Division of Computer, Electrical and Surveying Engineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 1263 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf