Effektivare hantering av åtgärder för jordtag efter besiktning
University West, Department of Engineering Science, Division of Computer, Electrical and Surveying Engineering.
2016 (Swedish)Independent thesis Basic level (university diploma), 10 credits / 15 HE creditsStudent thesisAlternative title
More efficient handling of measures after inspection of earth electrodes (English)
Abstract [sv]

I Sverige ställs det hårda krav på säkerheten inom eldistribution. Jordning är en viktig del för att säkerställa att felbortkoppling, samt att personsäkerhet finns i näten. Kraven som ställs finns I olika nivåer: lagar, föreskrifter och standarder. Ellagen är generellt utformad när det gäller elsäkerhet. I föreskrifter ställs mer specificerade krav, men inte någon vägledning till hur de uppnås. Det är i standarder som utförandet beskrivs. De gällande standarderna inom området är flera och ofta svåra att tyda. Problemet med tydningen kommer från att det är en rådande standard som är utformad för att vara applicerbar inom hela Europa. Detta är problematiskt då markförhållandena som råder skiljer sig avsevärt.

En utvärdering av Ellevios befintliga besiktningsprocess har gjorts. Parallellt med denna utvärdering har ett nytt betraktningssätt tagits fram med den erhållna kunskapen från litteraturstudierna. Det nya betraktningssättet anses vara mer i linje med de krav som ställs. Därför ges en rekommendation att ändra på befintlig besiktningsprocess. Ett klargörande av vad som skall betraktas som ett underkänt jordtag har lett till att Ellevios definition av underkända jordtag har i rapporten visats vara delvis felaktiga.

Abstract [en]

In Sweden, there are strict requirements for safety in power distribution grids. Grounding is an important part of ensuring that fault clearance, as well as personal safety exists in the grid. The requirements are stated in different levels: laws, regulations and standards. The Electricity Act is generally formed regarding electrical safety. The regulations are more specific requirements, but does not provide any guidance as to how they are achieved. There are standards which describes more detailed guidance. The current standards in this area are numerous and often difficult to interpret. The problem with interpreting the standards is a result from the fact that it is a ruling standard formed to be applicable within the whole of

Europe. This comes with some issues, specifically since the ground conditions vary a lot throughout different regions. An evaluation of Ellevios existing inspection process has been made. In parallel with this evaluation, a new model has been developed with the knowledge gained from the literature studies. The new model is considered to be more in line with the requirements. Therefore, a recommendation is made to change the existing inspection process. A clarification of what constitutes a faulty earth electrode has resulted in that Ellevios definition of a faulty earth electrode is partially incorrect.

Place, publisher, year, edition, pages
2016. , 31 p.
Keyword [sv]
Eldistribution, säkerhet
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:hv:diva-10261Local ID: XEL500OAI: oai:DiVA.org:hv-10261DiVA: diva2:1057617
Subject / course
Electrotechnology
Educational program
Elkraft
Supervisors
Examiners
Available from: 2016-12-19 Created: 2016-12-12 Last updated: 2016-12-19Bibliographically approved