Utredning av variablerna som påverkar storleken på brytspänningen i lindningskopplare
Högskolan Väst, Institutionen för ingenjörsvetenskap, Avd för automationssystem.
2015 (svensk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgaveAlternativ tittel
Investigation of the variables that affect the recovery voltage in tap-changers (engelsk)
Abstract [sv]

Brytspänningen är den spänning som uppkommer när överkopplingsmotståndet i lindningskopplaren lämnar sitt föregående läge vid omkoppling. Storleken på brytspänningen i lindningskopplaren beror på hur stor läckinduktansen är. Är den inte känd så kan brytspänningen istället beräknas med hjälp av FEM-programmet ACE (internt ABB-program) i samband med Mathcad. I ACE beräknas först reaktanserna i p.u-enheter mellan lindningarna och hur stora de är beror på lindningslayouten. Det är tidskrävande att använda ACE och Mathcad och uppgiften är att utreda de parametrar som påverkar storleken på brytspänningen samt att ta fram en förenklad beräkning av densamma.

Genom simulering i ACE av en mängd olika lindningslayouter visar det sig snart att det är alltför många parametrar som påverkar reaktanserna. De förenklingar som trots det har tagits fram är lite för grova för att det ska vara pålitligt. Mathcad är än mer komplext med tunga beräkningar som inte är lätta att förenkla.

Arbetet har ändå gett mer kunskap om hur reaktanserna påverkas av geometrierna i lindningarna och kommer att vara till viss nytta, även om det inte gick att förenkla ACE- och Mathcadberäkningarna så som var tänkt.

Abstract [en]

The recovery voltage is the voltage that occur when the transition resistor in the tap-changer leaves its previous position during an operation cycle. The amplitude of the recovery voltage depends on the leakage inductance.

If the leakage inductance is unknown, the recovery voltage can instead be calculated using a FEM-program called ACE (internal ABB-program) in conjunction with Mathcad. First, the reactances between the windings are calculated in per unit (p.u) using ACE and they depend on the winding layout. It is time consuming to use ACE and Mathcad and the task has been to investigate the parameters that affects the recovery voltage and to develop a simplified calculation of it.

Through simulation using ACE of a number of different winding layouts one soon comes to the conclusion that there are simply too many parameters affecting the reactances. Although the simplified calculations that despite this has been developed, they soon prove to be too rough to be useful. Mathcad is even more complex with heavy calculations that are not easy to grasp.

However, this thesis has given more knowledge about the way the reactances are affected by the geometry of the windings, even though it was not possible to in a reasonable way simplify the calculation of ACE and Mathcad.

sted, utgiver, år, opplag, sider
2015. , s. 16
Emneord [en]
Tap-changer, recovery voltage, leakage inductance
Emneord [sv]
Lindningskopplare, brytspänning, läckinduktans
HSV kategori
Identifikatorer
URN: urn:nbn:se:hv:diva-7467Lokal ID: EXC585OAI: oai:DiVA.org:hv-7467DiVA, id: diva2:798006
Fag / kurs
Electrotechnology
Utdanningsprogram
Elkraft
Veileder
Examiner
Tilgjengelig fra: 2015-03-25 Laget: 2015-03-25 Sist oppdatert: 2015-03-25bibliografisk kontrollert

Open Access i DiVA

fulltext(631 kB)250 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 631 kBChecksum SHA-512
3f8f8bd7a734d41a003f2e7851c9a5c8b356910781215f8227a64e576f6307292c0aece91abb4873e782a3da3713308d85a85a45aed4467bb574b1aa8e49eb98
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 250 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 568 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf