Driftinformation
Ett driftavbrott i samband med versionsuppdatering är planerat till 10/12-2024, kl 12.00-13.00. Under den tidsperioden kommer DiVA inte att vara tillgängligt
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Hantering av reaktiv effektproduktion som uppstår vid kablifiering av distributionsnätet i Lidköping
Högskolan Väst, Institutionen för ingenjörsvetenskap, Avdelningen för Industriell ekonomi, Elektro- och Maskinteknik.
2021 (Svenska)Självständigt arbete på grundnivå (kandidatexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)Alternativ titel
Management of reactive power production arising from cabling of the distribution grid in Lidköping (Engelska)
Abstract [sv]

Lidköping Elnät har på senare tid märkt av en ökad reaktiv effektgenerering från sitt nät, ett problem som till stora delar härrör från kablifiering och den ökade kapacitan sen som följerav detta. Problem som uppstår är bland annat spänningshöjningar ute i nätet, att kablar blir överbelastade av ström. Dessutom begränsar avtalet med Vattenfall mängden reaktiv effekt som gratis får matas upp på regionnätet. Denna studie har samlat ihop lokal nätdata som sedan använts för beräkningar i syfte att undersöka hur stor den reaktiva effekten är, hur stor den skulle bli vid extrema driftlägen så som ett obelastat nät, samt hur mycket den reaktiva effekten skulle öka om all luftledning som finns i nätet idag skulle ersättas med kabel. Två fall har undersökts. Det ena är hela Lidköping Elnäts 40 kV-nät och det andra är en utvald 10 kV-grupp i ett område i landsbygdsmiljö med långa sträckor luftledning och som förväntas kunna generera mycket reaktiv effekt vid en kablifiering. Undersökningen utfördes genom insamling av nätdata från Lidköping Elnätsdokumentation, som sammanställdes och analyserades dels i Excel, dels genom enlastflödesberäkning i programmet PowerWorld Simulator. Intressant data från de två fallenär hur mycket reaktiv effekt som genereras, var den genereras, hur stora effektflöden somgår genom ledningsnätet och slutligen når anslutningspunkten mot Vattenfall. Det är ävenintressant att undersöka storlek på spänningsvariationerna på några punkter i nätet. Resultaten av handberäkningar och beräkningar i programvaran har jämförts mot varandra och båda visar tydligt att det är landsbygdsområden som är hårdast utsatta för den reaktiva effektgenereringen, detta för att landsbygden i många fall har långa ledningssträckor med relativt låg last. Den framtida kablifieringen kommer ytterligare att öka på dessa problem och vissa områden kommer att få mer än dubblad reaktiv effektgenerering. Faskompensering i form av shuntreaktor införs i beräkningarna och de nya förutsättningarna testas i olika konfigurationer för att kunna lämna flera alternativ. Faskompensering ger goda resultat, med hjälp av två 10 Mvar-reaktorer och någon enstaka 2 Mvar-reaktor kan all reaktiv effektproduktion kompenseras. Spänningshöjningen blir som mest några enstaka procent och motverkas lätt med lindningskopplare.

Abstract [en]

Lidköping Elnät has recently noticed an increase in reactive power generation from its network, a problem that comes from cabling and the increased reactive power generation that follows from this. Problems that arise include voltage increases in the grid, cables being overloaded. The agreement with Vattenfall also limits the amount of reactive power that can be supplied to the regional grid free of charge. This study has collected local network data which then is used for calculations in order to investigate how large the reactive powerproduction is, how large it would be in extreme operating conditions such as an unloaded network, and how much the reactive power generation would increase if all overhead lines in the network today would be replaced by cables. Two cases have been investigated. One is the entire 40 kV network in Lidköping. The other is a selected 10 kV group in an area of rural environment with long stretches of overhead lines, which is expected to generate much reactive power when being cabled. The survey has been carried out by collecting network data from Lidköping Elnät's documentation, which was compiled and analyzed partly in Excel and partly through loadflow calculations in the PowerWorld Simulator program. Interesting result from the two cases is how much reactive power is generated, where it is generated, how large power flows go through the network and finally reach the connection point to Vattenfall. It is also interesting to examine the magnitude of the voltage variations at some points in the network. The results calculations in excel and calculations using the PowerWorld Simulator program have been compared with each other and both clearly show that it is rural areas that are most exposed to the reactive power generation. This because the countryside in many cases has long lines with relatively low loads. The future cabling will further increase these problems and some areas will experience more than doubled reactive power generation. Power factor compensation using shunt reactors are introduced in the calculations and the new conditions are tested in different configurations in order to provide several alternatives. Power factor compensation gives good results and with two 10 Mvar reactors and a single 2 Mvar reactor all reactive power production can be compensated. The voltage increase is at most a few percent and is easily taken care of by using the transformer tap changers.

Ort, förlag, år, upplaga, sidor
2021. , s. 39
Nyckelord [sv]
Elnät, effekt
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:hv:diva-16362Lokalt ID: EXE511OAI: oai:DiVA.org:hv-16362DiVA, id: diva2:1531797
Ämne / kurs
Elektroteknik
Utbildningsprogram
Elektroingenjör - Elkraft
Handledare
Examinatorer
Tillgänglig från: 2021-03-01 Skapad: 2021-02-26 Senast uppdaterad: 2021-03-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Av organisationen
Avdelningen för Industriell ekonomi, Elektro- och Maskinteknik
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 405 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf