Studie av övertoners inverkan på relätripptiden hos ett elektromekaniskt överströmsrelä
Högskolan Väst, Institutionen för ingenjörsvetenskap, Avdelningen för Industriell ekonomi, Elektro- och Maskinteknik.
Högskolan Väst, Institutionen för ingenjörsvetenskap, Avdelningen för Industriell ekonomi, Elektro- och Maskinteknik.
2019 (Svenska)Självständigt arbete på grundnivå (yrkesexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)Alternativ titel
Study the effect of harmonics on the relay trip time of an electromechanical overcurrent relay (Engelska)
Abstract [sv]

Ett uppmärksammat problem i elnätet är den ökande halten av övertoner. I ett elnät som är fritt från övertoner förekommer enbart en grundton men i vissa fall förekommer strömmar, och spänningar, med andra frekvenser och då innehåller nätet en viss halt övertoner. När anslutna belastningar är olinjära uppstår övertoner. Det är huvudsakligen ökningen av dessa typer av belastningar i elnätet, till exempel elbilsladdning och datorer, som ger upphov till den ökande övertonshalten.

Med anledning av ovannämnda problem med övertoner utförs detta examensarbetet på uppdrag av Megger Sweden AB i Stockholm. Syftet är att studera övertoners inverkan på relätripptiden hos ett elektromekaniskt överströmrelä som finns installerad i kraftnätets kontrollanläggningar.

Testerna utförs med testinstrumentet Sverker 900 och med ett elektromekaniskt överströmsrelä, ett RI-relä av märket ASEA. För testning av RI-reläet följs en svensk standard, en kommande internationell standard och instruktioner från uppdragsgivare. Resultaten från testerna visar på skillnader mellan tripptiden med övertoner och tripptiden för enbart grundtonen.

Slutsatser baserade på studiens resultat är dels att överströmsreläet är långsammare vid svaga strömmar, det vill säga 2,8 A och 3 A, eller har för långa tripptider i förhållande till beteendet utan övertoner. Dels att det är svårt att säkerställa ett signifikant samband mellan närvaron av övertoner och påverkan av relätripptiden vid medel och starka strömmar, det vill säga 4 A till 8 A, eller vid kortare tripptider.

Baserat på studiens resultat skulle det vara intressant att testa med flera övertonsnivåer. En rekommendation för liknande framtida studier är att bara testa vid låga strömmar, långa tripptider och långsamma diskhastigheter, eftersom detta skulle underlätta möjligheten att uppnå en mer överskådlig resultatanalys.

Abstract [en]

A problem that has been noticed in the electricity grid is the increase in level of harmonics. In some cases, there may also be currents or voltages with frequencies that differ from the fundamental tone and this leads to the grid having harmonics meaning that when loads and components in the electricity grid are not sinusoidal, harmonics occur. For example, an increase in these types of loads e.g. charging an electric car or computers, in the electricity grid gives rise to an increasing harmonic content.

In view of the aforementioned, this thesis has been carried out in collaboration with the Megger Sweden AB, Stockholm, as the official client for this study. The purpose here is to study the effect of harmonics on the relay trip time of an electromechanical overcurrent relay that is installed in the power grid's control facilities.

The tests are performed with the test instrument Sverker 900 and an electromechanical overcurrent relay, ASEA RI. For testing the RI relay, a Swedish standard, an upcoming international standard as well as instructions from the client have been thoroughly followed and applied. The results of the tests shows the difference between the trip time with harmonics and the trip time for the fundamental tone.

Conclusions based on the results are partly that the overcurrent relay is slower at weak currents, that is 2.8A and 3A respectively, as well as for long trip times in relation to the behavior without harmonics. According to the findings conducted herein, there is no significant correlation between the presence of harmonics and the influence of the relay trip time on medium and strong currents, between 4A-8A, or on shorter trip times.

By reason of the time constraint experienced in conducting this study, the results and findings reached leaves a sound potential and promise for future tests conducted at different harmonic levels. A future recommendation for similar studies will be to test only at low currents, long trip times and slow disk speeds as this would facilitate the possibility of fulfilling a more robust result analysis.

Ort, förlag, år, upplaga, sidor
2019. , s. 30
Nyckelord [sv]
Elnät, övertoner
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:hv:diva-13765Lokalt ID: EXE510, EXE511OAI: oai:DiVA.org:hv-13765DiVA, id: diva2:1302594
Ämne / kurs
Elektroteknik
Utbildningsprogram
Elkraft
Handledare
Examinatorer
Tillgänglig från: 2019-04-17 Skapad: 2019-04-05 Senast uppdaterad: 2019-04-17Bibliografiskt granskad

Open Access i DiVA

fulltext(1245 kB)129 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1245 kBChecksumma SHA-512
a0fec166e175ff9ce1d51383761ceb1c7257a6d3a01203e0fdc9594c045d5d6c11b10b5e784204dcd5589d11fbaacc55d4d50c6eb765cf50eae61002bb28dd07
Typ fulltextMimetyp application/pdf

Av organisationen
Avdelningen för Industriell ekonomi, Elektro- och Maskinteknik
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 129 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 465 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf