Bearing current and shaft voltage measurement in electrical motors
Högskolan Väst, Institutionen för ingenjörsvetenskap, Avdelningen för data-, elektro- och lantmäteriteknik.
2017 (Engelska)Självständigt arbete på grundnivå (yrkesexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Due to the fast-rising voltage pulses of pulse width modulated drives, the generated shaft voltage of electrical motors causes electrical discharge currents in bearings. These discharges can cause bearing failure leading to costly maintenance and unexpected production stops. To eliminate the raised shaft voltage, several techniques are used such as shaft grounding brushes, insulated bearings and conductive grease. The possibility to measure discharge activity on a PWM driven induction motor offers a tool for researchers to test different bearings in electric motors. In order to measure the shaft voltages and bearing currents, modifications of an induction motor are made firstly using 3D software and then on the physical motor. By insulating the bearing from the frame and attaching a copper ring to the bearings outer race bearing currents can be measured. The combined measurements of shaft voltage, bearing currents and frame currents shows the bearings conductive states at low speed, and insulated state at higher speed. Electrical discharge activity (DA) is observed as shaft voltage raises, resulting in a bearing current spike and shaft voltage drops rapidly while stator current is unaffected.

Experimental tests were performed with a sample bearing at different operating conditions, such as operating speed, temperature, motor load, etc., to determine the effect of the common mode voltages on bearing currents and shaft voltages. At low temperatures between 23-26 ˚C and motor speeds above 1000 rpm EDM currents were observed. On temperatures above 40 ˚C no major EDM currents were observed regardless of rpm due to the bearing remaining in an ohmic conductive state. The modifications of the motor have shown to give reliable bearing current and shaft voltage measurements that can help in future research in this area.

Ort, förlag, år, upplaga, sidor
2017. , s. 50
Nyckelord [en]
Modulated drive, electrical motors, production
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:hv:diva-10722Lokalt ID: EXM505OAI: oai:DiVA.org:hv-10722DiVA, id: diva2:1075152
Ämne / kurs
Elektroteknik
Utbildningsprogram
Elkraft
Handledare
Examinatorer
Tillgänglig från: 2017-02-20 Skapad: 2017-02-17 Senast uppdaterad: 2017-02-20Bibliografiskt granskad

Open Access i DiVA

fulltext(4283 kB)15831 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 4283 kBChecksumma SHA-512
78358cd24ef5c42d79c54de82cbfa62c696e57e1b08dd1de388d15f3312dd20a216e7072314d0591adf16fd48b9f65beb34c16496f7de0dc6cdabb4fe6bc5531
Typ fulltextMimetyp application/pdf

Av organisationen
Avdelningen för data-, elektro- och lantmäteriteknik
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 15855 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 715 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf