Bearing current and shaft voltage measurement in electrical motors
Högskolan Väst, Institutionen för ingenjörsvetenskap, Avdelningen för data-, elektro- och lantmäteriteknik.
2017 (engelsk)Independent thesis Basic level (professional degree), 10 poäng / 15 hpOppgave
Abstract [en]

Due to the fast-rising voltage pulses of pulse width modulated drives, the generated shaft voltage of electrical motors causes electrical discharge currents in bearings. These discharges can cause bearing failure leading to costly maintenance and unexpected production stops. To eliminate the raised shaft voltage, several techniques are used such as shaft grounding brushes, insulated bearings and conductive grease. The possibility to measure discharge activity on a PWM driven induction motor offers a tool for researchers to test different bearings in electric motors. In order to measure the shaft voltages and bearing currents, modifications of an induction motor are made firstly using 3D software and then on the physical motor. By insulating the bearing from the frame and attaching a copper ring to the bearings outer race bearing currents can be measured. The combined measurements of shaft voltage, bearing currents and frame currents shows the bearings conductive states at low speed, and insulated state at higher speed. Electrical discharge activity (DA) is observed as shaft voltage raises, resulting in a bearing current spike and shaft voltage drops rapidly while stator current is unaffected.

Experimental tests were performed with a sample bearing at different operating conditions, such as operating speed, temperature, motor load, etc., to determine the effect of the common mode voltages on bearing currents and shaft voltages. At low temperatures between 23-26 ˚C and motor speeds above 1000 rpm EDM currents were observed. On temperatures above 40 ˚C no major EDM currents were observed regardless of rpm due to the bearing remaining in an ohmic conductive state. The modifications of the motor have shown to give reliable bearing current and shaft voltage measurements that can help in future research in this area.

sted, utgiver, år, opplag, sider
2017. , s. 50
Emneord [en]
Modulated drive, electrical motors, production
HSV kategori
Identifikatorer
URN: urn:nbn:se:hv:diva-10722Lokal ID: EXM505OAI: oai:DiVA.org:hv-10722DiVA, id: diva2:1075152
Fag / kurs
Electrotechnology
Utdanningsprogram
Elkraft
Veileder
Examiner
Tilgjengelig fra: 2017-02-20 Laget: 2017-02-17 Sist oppdatert: 2017-02-20bibliografisk kontrollert

Open Access i DiVA

fulltext(4283 kB)15831 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 4283 kBChecksum SHA-512
78358cd24ef5c42d79c54de82cbfa62c696e57e1b08dd1de388d15f3312dd20a216e7072314d0591adf16fd48b9f65beb34c16496f7de0dc6cdabb4fe6bc5531
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 15855 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 715 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf